Initial energy for elective external cardioversion of persistent atrial fibrillation

被引:71
作者
Joglar, JA
Hamdan, MH
Ramaswamy, K
Zagrodzky, JD
Sheehan, CJ
Nelson, LL
Andrews, TC
Page, RL
机构
[1] Univ Texas, SW Med Ctr, Dept Internal Med Cardiol Clin Cardiac Electrophy, Dallas, TX USA
[2] Dallas Vet Affairs Med Ctr, Dallas, TX USA
关键词
D O I
10.1016/S0002-9149(00)00932-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We conducted a prospective randomized study to determine the safety and efficacy rate of 3 commonly used energy levels (100, 200, and 360 J) for elective direct-current cardioversion of persistent atrial fibrillation. When compared with 100 and 200 J, the initial success rate with 360 J was significantly higher (14%, 39%, and 95%, respectively), and patients randomized to 360 J ultimately required less total energy and a lower number of shocks.
引用
收藏
页码:348 / +
页数:4
相关论文
共 12 条
[1]   Cardiac troponin I levels are normal or minimally elevated after transthoracic cardioversion [J].
Allan, JJ ;
Feld, RD ;
Russell, AA ;
Ladenson, JH ;
Rogers, MAM ;
Kerber, RE ;
Jaffe, AS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (04) :1052-1056
[2]   Active compression cardioversion for refractory atrial fibrillation [J].
Cohen, TJ ;
Ibrahim, B ;
Denier, D ;
Haji, A ;
Quan, WL .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (03) :354-&
[3]  
DALZELL GWN, 1990, Q J MED, V76, P903
[4]   THE OPTIMAL TECHNIQUE FOR ELECTRICAL CARDIOVERSION OF ATRIAL-FIBRILLATION [J].
EWY, GA .
CLINICAL CARDIOLOGY, 1994, 17 (02) :79-84
[5]   OPTIMAL TECHNIQUE FOR ELECTRICAL CARDIOVERSION OF ATRIAL-FIBRILLATION [J].
EWY, GA .
CIRCULATION, 1992, 86 (05) :1645-1647
[6]   Time course of troponin I, myoglobin, and cardiac enzyme release after electrical cardioversion [J].
Georges, JL ;
Spentchian, M ;
Caubel, C ;
Collignon, I ;
Schwob, J ;
Livarek, B ;
Normand, JP .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (07) :825-&
[7]  
JONES DL, 1994, IMPLANTABLE CARDIOVE, P29
[8]   ENERGY, CURRENT, AND SUCCESS IN DEFIBRILLATION AND CARDIOVERSION - CLINICAL-STUDIES USING AN AUTOMATED IMPEDANCE-BASED METHOD OF ENERGY ADJUSTMENT [J].
KERBER, RE ;
MARTINS, JB ;
KIENZLE, MG ;
CONSTANTIN, L ;
OLSHANSKY, B ;
HOPSON, R ;
CHARBONNIER, F .
CIRCULATION, 1988, 77 (05) :1038-1046
[9]  
LOWN B, 1962, JAMA-J AM MED ASSOC, V182, P548
[10]   Plasma levels of troponin T after electrical cardioversion of atrial fibrillation and flutter [J].
Neumayr, G ;
Hagn, C ;
Ganzer, H ;
Friedrich, G ;
Pechlaner, C ;
Joannidis, M ;
Schratzberger, P ;
Wiedermann, CJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (10) :1367-+