Embolic protection devices for carotid artery stenting: better results than stenting without protection?

被引:92
作者
Zahn, R [1 ]
Mark, B
Niedermaier, N
Zeymer, U
Limbourg, P
Ischinger, T
Haerten, K
Hauptmann, KE
von Leitner, ER
Kasper, W
Tebbe, U
Senges, J
机构
[1] Herzzentrum, Ludwigshafen, Germany
[2] Klinikum Stadt Ludwigshafen, D-6700 Ludwigshafen, Germany
[3] Stadt Krankenhaus, Worms, Germany
[4] Stadt Klinikum, Munich, Germany
[5] Marien Hosp, Wesel, Germany
[6] Krankenhaus Barmherzigen Bruder, Trier, Germany
[7] Klinikum Siloah, Hannover, Germany
[8] St Josef Hosp, Wiesbaden, Germany
[9] Klinikum Lippe Detmold, Detmold, Germany
关键词
carotid arteries; carotid artery stenting; protection devices; angioplasty;
D O I
10.1016/j.ehj.2004.06.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Carotid artery stenting (CAS) for carotid artery stenoses has become an alternative to carotid endarterectomy. However, CAS itself can cause cerebral ischaemic events. Embolic protection devices (PD) promise to reduce the incidence of these events. Methods and results From July 1996 to March 2003, 1483 patients from 26 hospitals were included in the prospective CAS Registry of the ALKK study group. A PD was used in 668 of 1483 patients (45%). The use of a PD has grown rapidly over the years and reached 100% in 2003. Patients treated with a PD had prior carotid artery dilatation more often (3.5% versus 1%, p < 0.001), a prior myocardial infarction (34% versus 27.4%, p = 0.007) and a history of arterial hypertension (89.9% versus 78.6%, p = 0.007) compared to patients treated without a PD. A thrombus was more often visible in patients treated under distal protection (16.5% versus 8%, p < 0.001). The use of a PD led to a 10-min longer intervention (45 min versus 35 min median, p < 0.001). Patients treated with a PD had a tower rate of ipsilateral stroke (1.7% versus 4.1%, p = 0.007) and a lower rate of all non-fatal strokes and all deaths (2.1% versus 4.9%, p = 0.004) during the hospital stay. This was confirmed by multiple logistic regression analysis (adjusted OR = 0.45, 95% CI: 0.23-0.91, p = 0.026). A similar reduction could be found for symptomatic as well as asymptomatic carotid artery stenoses. Conclusion Since 1996 there has been a steady increase in the use of PDs for CAS, with a 100% use in 2003. The use of a PD may tower the rate of ipsilateral strokes during CAS. (C) 2004 The European Society of Cardiology. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1550 / 1558
页数:9
相关论文
共 31 条
[1]   Multicenter evaluation of carotid artery stenting with a filter protection system [J].
Al-Mubarak, N ;
Colombo, A ;
Gaines, PA ;
Iyer, SS ;
Corvaja, N ;
Cleveland, TJ ;
Macdonald, S ;
Brennan, C ;
Vitek, JJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) :841-846
[2]   Effect of the distal-balloon protection system on microembolization during carotid stenting [J].
Al-Mubarak, N ;
Roubin, GS ;
Vitek, JJ ;
Iyer, SS ;
New, G ;
Leon, MB .
CIRCULATION, 2001, 104 (17) :1999-2002
[3]   MEASUREMENTS OF ACUTE CEREBRAL INFARCTION - A CLINICAL EXAMINATION SCALE [J].
BROTT, T ;
ADAMS, HP ;
OLINGER, CP ;
MARLER, JR ;
BARSAN, WG ;
BILLER, J ;
SPILKER, J ;
HOLLERAN, R ;
EBERLE, R ;
HERTZBERG, V ;
RORICK, M ;
MOOMAW, CJ ;
WALKER, M .
STROKE, 1989, 20 (07) :864-870
[4]  
Brown MM, 2001, LANCET, V357, P1729
[5]   Comparison of hemodynamic cerebral ischemia and microembolic signals detected during carotid endarterectomy and carotid angioplasty [J].
Crawley, F ;
Clifton, A ;
Buckenham, T ;
Loosemore, T ;
Taylor, RS ;
Brown, MM .
STROKE, 1997, 28 (12) :2460-2464
[6]   Protected carotid stenting - Clinical advantages and complications of embolic protection devices in 442 consecutive patients [J].
Cremonesi, A ;
Manetti, R ;
Setacci, F ;
Setacci, C ;
Castriota, F .
STROKE, 2003, 34 (08) :1936-1941
[7]  
DIENER HC, 1991, STROKE, V22, P1229
[8]   Randomised trial of endarterectomy for recently symptomatic carotid stenosis: final results of the MRC European carotid surgery trial (ECST) [J].
Farrell, B ;
Fraser, A ;
Sandercock, P ;
Slattery, J ;
Warlow, CP .
LANCET, 1998, 351 (9113) :1379-1387
[9]   With or without protection? The second important question in carotid artery stenting [J].
Forsting, M .
STROKE, 2004, 35 (01) :E20-E21
[10]   Initial multicenter experience with a novel distal protection filter during carotid artery stent implantation [J].
Grube, E ;
Colombo, A ;
Hauptmann, E ;
Londero, H ;
Reifart, N ;
Gerckens, U ;
Stone, GW .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (02) :139-146