Measurement of gait parameters from free moving subjects

被引:15
作者
Lackovic, I
Bilas, V
Santic, A
Nikolic, V
机构
[1] Univ Zagreb, Fac Elect & Comp Engn, HR-10000 Zagreb, Croatia
[2] Univ Zagreb, Sch Med, HR-10000 Zagreb, Croatia
关键词
quantitative gait analysis; ambulatory subjects; on-line monitoring; vertical force measurement; capacitive force transducer; IR force transducer; IR telemetry; low-power design; temporal gait parameters; data processing;
D O I
10.1016/S0263-2241(99)00063-9
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper a telemetry system for real-time force measurement in the legs and crutches or cane is presented. The system provides a quantitative gait analysis of orthopaedic patients with details, which are often hidden to a visual observation. Three vertical force components in each leg are measured. For this purpose flat and pliable capacitive sensors, which are placed on the sole of the shoes, were developed. The infrared telemetry is applied to enable free and unconstrained movements of the patient inside a wide indoor environment. Measured forces, after transmission and processing on the receiver side, are presented on the computer monitor as eight channel time diagrams. An original software package (GAS) for on-line monitoring and processing of vertical force data was developed. The processing enables calculation of many diagnostically important parameters (e.g. temporal parameters, average force, force-time integral, sum of forces, etc.), spectral and time-frequency analysis and many other. As an example of clinical application,temporal parameters during ten strides for 20 normal subjects and 20 patients with lower extremities degenerative joint diseases were calculated and compared. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:121 / 131
页数:11
相关论文
共 13 条
[1]   TRANSDUCERS FOR FOOT PRESSURE MEASUREMENT - SURVEY OF RECENT DEVELOPMENTS [J].
COBB, J ;
CLAREMONT, DJ .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (04) :525-532
[2]  
DAVIS RB, 1995, BIOMEDICAL ENG HDB, P381
[3]  
Harris G F, 1996, IEEE Trans Rehabil Eng, V4, P360, DOI 10.1109/86.547938
[4]   ASSESSMENT OF GAIT USING COMPONENTS OF THE GROUND REACTION FORCE VECTOR [J].
JARRETT, MO ;
MOORE, PR ;
SWANSON, AJG .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1980, 18 (05) :685-688
[5]   THE USE OF GROUND REACTION MEASURING SHOES IN GAIT EVALUATION [J].
KLJAJIC, M ;
KRAJNIK, J .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1987, 8 (02) :133-142
[6]   Clinical gait analysis by neural networks: Issues and experiences [J].
Kohle, M ;
Merkl, D ;
Kastner, J .
TENTH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 1997, :138-143
[7]   A computer based vertical force monitoring and analysis system for gait evaluation [J].
Lackovic, I ;
Bilas, V ;
Santic, A .
TENTH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 1997, :238-243
[8]  
LACKOVIC I, 1998, P 8 IMEKO C MEAS CLI, P14
[9]   CAPACITIVE TRANSDUCER FOR CONTINUOUS MEASUREMENT OF VERTICAL FOOT FORCE [J].
MIYAZAKI, S ;
ISHIDA, A .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1984, 22 (04) :309-316
[10]  
Santic A., 1996, Proceedings. 11th International Symposium on Biomedical Engineering '96, P5