Comparison of different liquid chromatography methods for the determination of corticosteroids in biological matrices

被引:58
作者
Stolker, AAM
Schwillens, PLWJ
van Ginkel, LA
Brinkman, UAT
机构
[1] Natl Inst Publ Hlth & Environm, RIVM, Lab Residue Anal, NL-3720 BA Bilthoven, Netherlands
[2] Free Univ Amsterdam, Dept Analyt Chem, NL-1081 HV Amsterdam, Netherlands
关键词
solid-phase extraction; corticosteroids; steroids;
D O I
10.1016/S0021-9673(00)00725-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Various extraction techniques can be combined with column liquid chromatography (LC) and ultraviolet (UV) or mass spectrometric (MS) detection for the determination of synthetic corticosteroids in biological matrices. Target analysis of low concentrations of 25 mu g/kg of dexamethasone in feed can be performed by combining immunoaffinity chromatography (IAC) and LC with UV detection. A straightforward multi-analyte procedure is obtained by tandem solid-phase extraction (SPE) and subsequent LC-UV. However, the limits of detection for feed samples are then relatively poor, viz. 100 mu g/kg. 4 multi-analyte method which meets modern demands of about 5 mu g/kg detection limit requires one-step SPE combined with LC-MS analysis. As regards urine corticosteroids can be determined down to a level of 0.5 mu g/l by either SPE-LC-MS-MS or SPE(IAC)-LC-MS. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:55 / 67
页数:13
相关论文
共 15 条
[1]   Analysis of dexamethasone and betamethasone in bovine urine by purification with an ''on-line'' immunoaffinity chromatography high-performance liquid chromatography system and determination by gas chromatography mass spectrometry [J].
Bagnati, R ;
Ramazza, V ;
Zucchi, M ;
Simonella, A ;
Leone, F ;
Bellini, A ;
Fanelli, R .
ANALYTICAL BIOCHEMISTRY, 1996, 235 (02) :119-126
[2]  
Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.3.CO
[3]  
2-S
[4]   DETERMINATION OF DEXAMETHASONE IN URINE AND FECES OF TREATED CATTLE WITH NEGATIVE CHEMICAL-IONIZATION - MASS-SPECTROMETRY [J].
COURTHEYN, D ;
VERCAMMEN, J ;
DEBRABANDER, H ;
VANDENREYT, I ;
BATJOENS, P ;
VANOOSTHUYZE, K ;
VANPETEGHEM, C .
ANALYST, 1994, 119 (12) :2557-2564
[5]   On-line immunoaffinity chromatography high-performance liquid chromatography mass spectrometry for the determination of dexamethasone [J].
Creaser, CS ;
Feely, SJ ;
Houghton, E ;
Seymour, M ;
Teale, P .
ANALYTICAL COMMUNICATIONS, 1996, 33 (01) :5-8
[6]   Immunoaffinity chromatography combined on-line with high-performance liquid chromatography mass spectrometry for the determination of corticosteroids [J].
Creaser, CS ;
Feely, SJ ;
Houghton, E ;
Seymour, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 794 (1-2) :37-43
[7]   Quantitative determination of several synthetic corticosteroids by gas chromatography mass spectrometry after purification by immunoaffinity chromatography [J].
Delahaut, P ;
Jacquemin, P ;
Colemonts, Y ;
Dubois, M ;
DeGraeve, J ;
Deluyker, H .
JOURNAL OF CHROMATOGRAPHY B, 1997, 696 (02) :203-215
[8]  
*EU CRL NRL, 1998, P EU CRL NRL WORKSH
[9]  
*EUR COMM, 1993, OFF J EUR COMMUM L, V118, P64
[10]   Identification of main corticosteroids as illegal feed additives in milk replacers by liquid chromatography atmospheric pressure chemical ionisation mass spectrometry [J].
Fiori, M ;
Pierdominici, E ;
Longo, F ;
Brambilla, G .
JOURNAL OF CHROMATOGRAPHY A, 1998, 807 (02) :219-227