Comparative diagnostic performance of two commercial rapid tests for malaria in a non-endemic area
被引:35
作者:
De Monbrison, F
Gérome, P
Chaulet, JF
Wallon, M
Picot, S
Peyron, F
机构:
[1] Hop Croix Rousse, Serv Parasitol & Pathol Exot, F-69317 Lyon, France
[2] Hop Instruct Armees Desgenettes, Dept Biol, F-69998 Lyon, France
[3] Univ Lyon 1, Fac Med EA 3087, F-69365 Lyon, France
[4] Serv Parasitol & Mycol Med, F-69373 Lyon 08, France
关键词:
D O I:
10.1007/s10096-004-1202-9
中图分类号:
R51 [传染病];
学科分类号:
100401 ;
摘要:
In the study reported here, the diagnostic performance of two new rapid tests for the diagnosis of malaria was evaluated in symptomatic patients in a non-endemic area. Of 557 consecutive patients, 109 (19.6%) had documented malaria. For the NOW ICT MALARIA P. f./P.v. (Binax, Portland, ME, USA) and OptiMAL IT (Diamed, Cressier, Switzerland) tests, respectively, sensitivity values were 96.3% and 79.8% (P-value, 0.0001), and specificity values were 98.8% and 98.4%. The NOW ICT test did not detect two of 80 Plasmodium falciparum infections, and it generated false-positive results for five patients. The OptiMAL IT test failed to detect ten of the P falciparum infections, and it generated seven false-positive results. The results suggest that these rapid diagnostic tests for malaria may be useful, but they cannot replace microscopic examination of blood films.