Physiologic control of rotary blood pumps:: An in vitro study

被引:32
作者
Giridharan, GA
Pantalos, GM
Gillars, KJ
Koenig, SC
Skliar, M
机构
[1] Univ Utah, Dept Chem Engn, Salt Lake City, UT 84112 USA
[2] Univ Louisville, Jewish Hosp, Heart & Lung Inst, Dept Surg, Louisville, KY 40292 USA
关键词
D O I
10.1097/01.MAT.0000136652.78197.58
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Rotary blood pumps (RBPs) are currently being used as a bridge to transplantation as well as for myocardial recovery and destination therapy for patients with heart failure. Physiologic control systems for RBPs that can automatically and autonomously adjust the pump flow to match the physiologic requirement of the patient are needed to reduce human intervention and error, while improving the quality of life. Physiologic control systems for RBPs should ensure adequate perfusion while avoiding inflow occlusion via left ventricular (LV) suction for varying clinical and physical activity conditions. For RBPs used as left ventricular assist devices (LVADs), we hypothesize that maintaining a constant average pressure difference between the pulmonary vein and the aorta (DeltaPa) would give rise to a physiologically adequate perfusion while avoiding LV suction. Using a mock circulatory system, we tested the performance of the control strategy of maintaining a constant average DeltaPa and compared it with the results obtained when a constant average pump pressure head (DeltaP) and constant rpm are maintained. The comparison was made for normal, failing, and asystolic left heart during rest and at light exercise. The DeltaPa was maintained at 95 +/- 1 mm Hg for all the scenarios. The results indicate that the DeltaPa control strategy maintained or restored the total flow rate to that of the physiologically normal heart during rest (3.8 L/m) and light exercise (5.4 L/m) conditions. The DeltaPa approach adapted to changing exercise and clinical conditions better than the constant rpm and constant DeltaP control strategies. The DeltaPa. control strategy requires the implantation of two pressure sensors, which may not be clinically feasible. Sensorless RBP control using the DeltaPa algorithm, which can eliminate the failure prone pressure sensors, is being currently investigated.
引用
收藏
页码:403 / 409
页数:7
相关论文
共 29 条
[1]   Induction of ventricular collapse by an axial flow blood pump [J].
Amin, DV ;
Antaki, JF ;
Litwak, P ;
Thomas, D ;
Wu, ZJJ ;
Watach, M .
ASAIO JOURNAL, 1998, 44 (05) :M685-M690
[2]  
Araki K, 1998, ASAIO J, V44, pM708, DOI 10.1097/00002480-199809000-00082
[3]  
Boston JR, 2000, P AMER CONTR CONF, P3473
[4]  
DREW GA, 2000, LABVIEW AUTOMATIVE T, P92
[5]   Modeling and control of a brushless DC axial flow ventricular assist device [J].
Giridharan, CA ;
Skliar, M ;
Olsen, DB ;
Pantalos, GM .
ASAIO JOURNAL, 2002, 48 (03) :272-289
[6]  
GIRIDHARAN G, 2002, 10 C INT SOC ROT BLO
[7]   Control strategy for maintaining physiological perfusion with rotary blood pumps [J].
Giridharan, GA ;
Skliar, M .
ARTIFICIAL ORGANS, 2003, 27 (07) :639-648
[8]   Nonlinear controller for ventricular assist devices [J].
Giridharan, GA ;
Skliar, M .
ARTIFICIAL ORGANS, 2002, 26 (11) :980-984
[9]  
GREEN J, 1987, FUNDAMENTAL CARDIOVA
[10]  
GUYTON A.C., 1981, TXB MED PHYSL