An in vivo determination of total hip arthroplasty pistoning during activity

被引:104
作者
Lombardi, AV [1 ]
Mallory, TH [1 ]
Dennis, DA [1 ]
Komistek, RD [1 ]
Fada, RA [1 ]
Northcut, EJ [1 ]
机构
[1] Joint Implant Surg Inc, Columbus, OH 43215 USA
关键词
total hip arthroplasty; in vivo; gait; abduction; fluoroscopy; joint separation; wear;
D O I
10.1054/arth.2000.6637
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to determine to what extent hip joint separation occurs during normal gait on a treadmill and an abduction/adduction leg-lift maneuver in patients who have undergone total hip arthroplasty (THA). Eight patients who had a total of 10 successful, unconstrained THAs (Harris Hip Scores >90) performed successive gait motions on an electronically powered treadmill and an abduction/adduction leg lift while under fluoroscopy. The fluoroscopic video images were analyzed using a 3-dimensional model-fitting technique that converts 2-dimensional fluoroscopic images into 3-dimensional real-time images. Hip joint separation was determined to be present if the amount of separation was >0.75 mm, the calculated linear error. During both activities, all 10 THAs experienced femoral head/acetabular component separation. For gait, the maximum amount of separation was 2.8 mm. while the minimum amount was 0.8 mm (average, 1.2 mm). For abduction/adduction leg lift, the maximum amount of separation was 3.0 mm, while the minimal amount was 1.7 mm (average. 2.4 mm). It appears that the femoral head separates from the acetabular component but remains in contact with the superior-most tip of the component. Potential detrimental effects resulting from hip joint separation include premature polyethylene wear and component loosening. Wear may be enhanced because of the creation of multidirectional wear vectors or excessive loads resulting from eccentric femoral head pivoting. These data may be valuable in hip simulation studies to better duplicate wear patterns observed in retrieval analysis.
引用
收藏
页码:702 / 709
页数:8
相关论文
共 49 条
[1]
HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[2]
Bergmann G, 1997, CLIN ORTHOP RELAT R, P190
[3]
Bono J V, 1994, J Arthroplasty, V9, P119, DOI 10.1016/0883-5403(94)90059-0
[4]
Brand R A, 1994, J Arthroplasty, V9, P45, DOI 10.1016/0883-5403(94)90136-8
[5]
A MODEL OF LOWER-EXTREMITY MUSCULAR ANATOMY [J].
BRAND, RA ;
CROWNINSHIELD, RD ;
WITTSTOCK, CE ;
PEDERSEN, DR ;
CLARK, CR ;
VANKRIEKEN, FM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (04) :304-310
[6]
Charnley wear model for validation of hip simulators - Ball diameter versus polytetrafluoroethylene and polyethylene wear [J].
Clarke, IC ;
Good, V ;
Anissian, L ;
Gustafson, A .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (01) :25-36
[7]
CLARKE IC, 1991, TOTAL HIP ARTHROPLAS, P535
[8]
BIOMECHANICAL INVESTIGATION OF HUMAN HIP [J].
CROWNINSHIELD, RD ;
JOHNSTON, RC ;
ANDREWS, JG ;
BRAND, RA .
JOURNAL OF BIOMECHANICS, 1978, 11 (1-2) :75-85
[9]
USE OF OPTIMIZATION TECHNIQUES TO PREDICT MUSCLE FORCES [J].
CROWNINSHIELD, RD .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1978, 100 (02) :88-92
[10]
TELEMETRIC FORCE MEASUREMENTS ACROSS THE HIP AFTER TOTAL ARTHROPLASTY [J].
DAVY, DT ;
KOTZAR, GM ;
BROWN, RH ;
HEIPLE, KG ;
GOLDBERG, VM ;
HEIPLE, KG ;
BERILLA, J ;
BURSTEIN, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (01) :45-50