Analysis of tip malposition and correction in peripherally inserted central catheters placed at bedside by a dedicated nursing team

被引:153
作者
Trerotola, Scott O.
Thompson, Steven
Chittams, Jesse
Vierregger, Kristen S.
机构
[1] Univ Penn, Med Ctr, Dept Radiol, Div Intervent Radiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Med Ctr, Dept Nursing, Philadelphia, PA 19104 USA
[3] Univ Penn, Med Ctr, Dept Med, Ctr Clin Epidemiol & Biostat, Philadelphia, PA 19104 USA
关键词
D O I
10.1016/j.jvir.2007.01.020
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To analyze the patterns of postplacement tip malposition in peripherally inserted central catheters (PICCs) placed at bedside, and to describe results of bedside and imaging-guided correction of tip malposition. MATERIALS AND METHODS: With use of a quality assurance database, all episodes of tip malposition in PICCs placed at bedside were reviewed. Catheter tip location, success or failure of bedside repositioning (in a subset of patients, by using over-the-wire techniques), findings in the interventional radiology (IR) division, and tip correction method used in the IR suite (repositioning vs replacement) were determined with a review of medical records. RESULTS: During the 18-month study period, 2,367 attempts were made to place a PICC at bedside; 1,654 attempts (70%) were initially successful. Of these, 163 tips (10%) were malpositioned. Complete records for 132 malpositioned tips were available for analysis. Malpositioned tips were located in the ipsilateral internal jugular vein in 45 of the 132 cases (36%), axillary vein in 36 cases (27%), ipsilateral subclavian vein in 25 cases (19%), ipsilateral brachiocephalic vein in 15 cases (11%), contralateral subclavian vein in four cases (3%), contralateral brachiocephalic vein in two cases (2%), contralateral internal jugular vein in one case (1%), and subclavian tributary in one case (1%). In three cases (2%), the tip was coiled in the superior vena cava. Malposition was corrected with catheter exchange in 76 of the 132 cases (58%), repositioning in 48 cases (36%), or removal in one case (1%). Spontaneous correction occurred in seven of the 132 malpositioned tips (5%). One hundred nine tips (83%) were repositioned in the IR division with use of imaging guidance, with 100% success. Twenty-five attempts were made to correct malposition at bedside; 16 of those attempts (64%) were successful. CONCLUSION: Tip malposition is relatively frequent with bedside placement of PICCs. Preliminary data suggest that most malpositions can be corrected with bedside techniques. Spontaneous correction may occur but is relatively uncommon.
引用
收藏
页码:513 / 518
页数:6
相关论文
共 31 条
[1]   Venous thrombosis associated with the placement of peripherally inserted central catheters [J].
Allen, AW ;
Megargell, JL ;
Lynch, FC ;
Singh, H ;
Singh, Y ;
Waybill, PN .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (10) :1309-1314
[2]  
[Anonymous], 1998, J VASC ACCESS DEVICE, V3, P8, DOI 10.2309/108300898776087341
[3]   A nurse led peripherally inserted central catheter line insertion service is effective with radiological support [J].
Barber, JM ;
Booth, DM ;
King, JA ;
Chakraverty, S .
CLINICAL RADIOLOGY, 2002, 57 (05) :352-354
[4]   TECHNICAL NOTE - REPOSITIONING MISPLACED CENTRAL VENOUS CATHETERS [J].
CARRASCO, CH ;
RICHLI, WR ;
CHARNSANGAVEJ, C ;
WALLACE, S .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1987, 10 (04) :234-236
[5]   Factors predicting subcutaneous implanted central venous port function: The relationship between catheter tip location and port failure in patients with gynecologic malignancies [J].
Cohn, DE ;
Mutch, DG ;
Rader, JS ;
Farrell, M ;
Awantang, R ;
Herzog, TJ .
GYNECOLOGIC ONCOLOGY, 2001, 83 (03) :533-536
[6]  
DEITEL M, 1971, CAN J SURG, V14, P42
[7]  
Frey A M, 1995, J Intraven Nurs, V18, P280
[8]   Placement of peripherally inserted central catheters without fluoroscopy in children: Initial catheter tip position [J].
Fricke, BL ;
Racadio, JM ;
Duckworth, T ;
Donnelly, LF ;
Tamer, RM ;
Johnson, ND .
RADIOLOGY, 2005, 234 (03) :887-892
[9]   Evaluation of a unique, nurse-inserted, peripherally inserted central catheter program [J].
Gamulka, B ;
Mendoza, C ;
Connolly, B .
PEDIATRICS, 2005, 115 (06) :1602-1606
[10]   Ultrasonic locating devices for central venous cannulation: meta-analysis [J].
Hind, D ;
Calvert, N ;
McWilliams, R ;
Davidson, A ;
Paisley, S ;
Beverley, C ;
Thomas, S .
BMJ-BRITISH MEDICAL JOURNAL, 2003, 327 (7411) :361-364