Mobile phase compensation to improve NMR spectral properties during solvent gradients

被引:9
作者
Jayawickrama, DA
Wolters, AM
Sweedler, JV
机构
[1] Univ Illinois, Dept Chem, Urbana, IL 61801 USA
[2] Univ Illinois, Beckman Inst, Urbana, IL 61801 USA
关键词
D O I
10.1039/b301359f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A solvent compensation method based on flow injection analysis is used to obtain high quality nuclear magnetic resonance (NMR) spectra during solvent gradients. Using a binary solvent system containing D2O and CD3OD, NMR line broadening and chemical shift changes are observed with a 10% methanol per min solvent composition gradient. However, by creating a second equal but reverse gradient and combining the two solvent gradients before the NMR detector, the composition of solvent reaching the NMR flow cell is kept constant. We demonstrate a system using flow injection analysis of combining solvent gradients and show constant NMR spectral performance as a function of time as the combined flow has a constant solvent composition irrespective of the initial solvent gradient. Using this approach, methods can be developed to measure high quality NMR spectra during on-flow gradient LC-NMR experiments. The ultimate ability of this approach depends on the ability to compensate for the disturbance of the solvent gradient and reverse gradient by a pair of LC columns ( the analytical and reverse gradient columns).
引用
收藏
页码:421 / 426
页数:6
相关论文
共 32 条
[1]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - NUCLEAR MAGNETIC-RESONANCE ONLINE COUPLING [J].
ALBERT, K ;
BAYER, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1988, 7 (08) :288-293
[2]   DIRECT COUPLING OF OPEN-TUBULAR LIQUID-CHROMATOGRAPHY WITH MASS-SPECTROMETRY [J].
DEWIT, JSM ;
PARKER, CE ;
TOMER, KB ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1987, 59 (19) :2400-2404
[3]   MICROCOLUMN LIQUID-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED SPECTROMETRY INTERFACE USING A POTASSIUM-BROMIDE DISK [J].
FUJIMOTO, C ;
MORITA, T ;
JINNO, K ;
OCHIAI, S .
CHROMATOGRAPHIA, 1987, 23 (07) :512-516
[4]   CONTINUOUS INFRARED SPECTROSCOPIC ANALYSIS OF ISOCRATIC AND GRADIENT ELUTION REVERSED-PHASE LIQUID-CHROMATOGRAPHY SEPARATIONS [J].
GAGEL, JJ ;
BIEMANN, K .
ANALYTICAL CHEMISTRY, 1987, 59 (09) :1266-1272
[5]   OPTIMIZATION OF NMR AND HPLC CONDITIONS FOR LC-NMR [J].
GRIFFITHS, L .
ANALYTICAL CHEMISTRY, 1995, 67 (22) :4091-4095
[6]  
Griffiths L, 1998, MAGN RESON CHEM, V36, P104, DOI 10.1002/(SICI)1097-458X(199802)36:2<104::AID-OMR230>3.0.CO
[7]  
2-F
[8]  
HORI M, 1997, Patent No. 09229920
[9]   Rapid microfluidic mixing [J].
Johnson, TJ ;
Ross, D ;
Locascio, LE .
ANALYTICAL CHEMISTRY, 2002, 74 (01) :45-51
[10]   High-resolution NMR spectroscopy of sample volumes from 1 nL to 10 μL [J].
Lacey, ME ;
Subramanian, R ;
Olson, DL ;
Webb, AG ;
Sweedler, JV .
CHEMICAL REVIEWS, 1999, 99 (10) :3133-+