Monte Carlo simulation of time-dependent, transport-limited fluorescent boundary measurements in frequency domain

被引:8
作者
Pan, Tianshu [1 ]
Rasmussen, John C. [1 ]
Lee, Jae Hoon [1 ]
Sevick-Muraca, Eva M. [1 ]
机构
[1] Baylor Coll Med, Dept Radiol, Houston, TX 77030 USA
关键词
Monte Carlo; photon migration; transport limit; time dependent; radiative transfer equation; small animal tomography;
D O I
10.1118/1.2710549
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, we have presented and experimentally validated a unique numerical solver of the coupled radiative transfer equations (RTEs) for rapidly computing time-dependent excitation and fluorescent light propagation in small animal tomography. Herein, we present a time-dependent Monte Carlo algorithm to validate the forward RTE solver and investigate the impact of physical parameters upon transport-limited measurements in order to best direct the development of the RTE solver for optical tomography. Experimentally, the Monte Carlo simulations for both transport-limited and diffusion-limited propagations are validated using frequency domain photon migration measurements for 1.0%, 0.5%, and 0.2% intralipid solutions containing 1 mu M indocyanine green in a 49 cm 3 cylindrical phantom corresponding to the small volume employed in small animal tomography. The comparisons between Monte Carlo simulations and the numerical solutions result in mean percent error in amplitude and the phase shift less than 5.0% and 0.7 degrees, respectively, at excitation and emission wavelengths for varying anisotropic factors, lifetimes, and modulation frequencies. Monte Carlo simulations indicate that the accuracy of the forward model is enhanced using (i) suitable source models of photon delivery, (ii) accurate anisotropic factors, and (iii) accurate acceptance angles of collected photons. Monte Carlo simulations also show that the accuracy of the diffusion approximation in the small phantom depends upon (i) the ratio d(phantom)/l(tr), where d(phantom) is the phantom diameter and l(tr) is the transport mean free path; and (ii) the anisotropic factor of the medium. The Monte Carlo simulations validates and guides the future development of an appropriate RTE solver for deployment in small animal optical tomography. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1298 / 1311
页数:14
相关论文
共 30 条
[11]   Quantitative analysis of near-infrared tomography: sensitivity to the tissue-simulating precalibration phantom [J].
Jiang, SD ;
Pogue, BW ;
McBride, TO ;
Paulsen, KD .
JOURNAL OF BIOMEDICAL OPTICS, 2003, 8 (02) :308-315
[12]   FLUORESCENCE SPECTROSCOPY OF TURBID MEDIA - AUTOFLUORESCENCE OF THE HUMAN AORTA [J].
KEIJZER, M ;
RICHARDSKORTUM, RR ;
JACQUES, SL ;
FELD, MS .
APPLIED OPTICS, 1989, 28 (20) :4286-4292
[13]   Experimental validation of Monte Carlo modeling of fluorescence in tissues in the UV-visible spectrum [J].
Liu, Q ;
Zhu, CF ;
Ramanujam, N .
JOURNAL OF BIOMEDICAL OPTICS, 2003, 8 (02) :223-236
[14]   Accuracy of the diffusion equation to describe photon migration through an infinite medium: numerical and experimental investigation [J].
Martelli, F ;
Bassani, M ;
Alianelli, L ;
Zangheri, L ;
Zaccanti, G .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (05) :1359-1373
[15]   Determination of optical parameters of human breast tissue from spatially resolved fluorescence: a diffusion theory model [J].
Nair, MS ;
Ghosh, N ;
Raju, NS ;
Pradhan, A .
APPLIED OPTICS, 2002, 41 (19) :4024-4035
[16]   Fiber-optic bundle design for quantitative fluorescence measurement from tissue [J].
Pogue, BW ;
Burke, G .
APPLIED OPTICS, 1998, 37 (31) :7429-7436
[17]   LASER-INDUCED FLUORESCENCE SPECTROSCOPY AT ENDOSCOPY - TISSUE OPTICS, MONTE-CARLO MODELING, AND IN-VIVO MEASUREMENTS [J].
QU, JN ;
MACAULAY, C ;
LAM, S ;
PALCIC, B .
OPTICAL ENGINEERING, 1995, 34 (11) :3334-3343
[18]   Excitation-and-collection geometry insensitive fluorescence imaging of tissue-simulating turbid media [J].
Qu, JNY ;
Huang, ZJ ;
Hua, JW .
APPLIED OPTICS, 2000, 39 (19) :3344-3356
[19]   Radiative transport in fluorescence-enhanced frequency domain photon migration [J].
Rasmussen, John C. ;
Joshi, Amit ;
Pan, Tianshu ;
Wareing, Todd ;
McGhee, John ;
Sevick-Muraca, Eva M. .
MEDICAL PHYSICS, 2006, 33 (12) :4685-4700
[20]   QUANTITATION OF TIME-RESOLVED AND FREQUENCY-RESOLVED OPTICAL-SPECTRA FOR THE DETERMINATION OF TISSUE OXYGENATION [J].
SEVICK, EM ;
CHANCE, B ;
LEIGH, J ;
NIOKA, S ;
MARIS, M .
ANALYTICAL BIOCHEMISTRY, 1991, 195 (02) :330-351