Systematic Review: Comparative Effectiveness of Core-Needle and Open Surgical Biopsy to Diagnose Breast Lesions

被引:155
作者
Bruening, Wendy [1 ]
Fontanarosa, Joann [1 ]
Tipton, Kelley [1 ]
Treadwell, Jonathan R. [1 ]
Launders, Jason [1 ]
Schoelles, Karen [1 ]
机构
[1] ECRI Inst, Evidence Based Practice Ctr, Plymouth Meeting, PA 19462 USA
基金
美国医疗保健研究与质量局;
关键词
2-YEAR FOLLOW-UP; GUIDED CORE; STEREOTACTIC BIOPSY; ACCURACY; ULTRASOUND; EXPERIENCE; MASSES; MICROCALCIFICATIONS; COST; MAMMOGRAPHY;
D O I
10.7326/0003-4819-152-1-201001050-00190
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Most women undergoing breast biopsy are found not to have cancer. Purpose: To compare the accuracy and harms of different breast biopsy methods in average-risk women suspected of having breast cancer. Data Sources: Databases, including MEDLINE and EMBASE, searched from 1990 to September 2009. Study Selection: Studies that compared core-needle biopsy diagnoses with open surgical diagnoses or clinical follow-up. Data Extraction: Data were abstracted by 1 of 3 researchers and verified by the primary investigator. Data Synthesis: 33 studies of stereotactic automated gun biopsy; 22 studies of stereotactic-guided, vacuum-assisted biopsy; 16 studies of ultrasonography-guided, automated gun biopsy; 7 studies of ultrasonography-guided, vacuum-assisted biopsy; and 5 studies of freehand automated gun biopsy met the inclusion criteria. Low-strength evidence showed that core-needle biopsies conducted under stereotactic guidance with vacuum assistance distinguished between malignant and benign lesions with an accuracy similar to that of open surgical biopsy. Ultrasonography-guided biopsies were also very accurate. The risk for severe complications is lower with core-needle biopsy than with open surgical procedures (<1% vs. 2% to 10%). Moderate-strength evidence showed that women in whom breast cancer was initially diagnosed by core-needle biopsy were more likely than women with cancer initially diagnosed by open surgical biopsy to be treated with a single surgical procedure (random-effects odds ratio, 13.7 [95% CI, 5.5 to 34.6]). Limitation: The strength of evidence was rated low for accuracy outcomes because the studies did not report important details required to assess the risk for bias. Conclusion: Stereotactic-and ultrasonography-guided core-needle biopsy procedures seem to be almost as accurate as open surgical biopsy, with lower complication rates.
引用
收藏
页码:238 / U75
页数:19
相关论文
共 129 条
[1]  
Abdsaleh S, 2003, ACTA RADIOL, V44, P47
[2]   Sonographically guided 11-G directional vacuum-assisted breast biopsy as an alternative to surgical excision:: Utility and cost study in probably benign lesions [J].
Alonso-Bartolomé, P ;
Vega-Bolívar, A ;
Torres-Tabanera, M ;
Ortega, E ;
Acebal-Blanco, M ;
Garijo-Ayensa, F ;
Rodrigo, I ;
Muñoz-Cacho, P .
ACTA RADIOLOGICA, 2004, 45 (04) :390-396
[3]  
Ambrogetti Daniela, 2003, Radiol Med, V106, P313
[4]  
[Anonymous], 2008, Cancer Facts Figures 2008
[5]  
Antley CM., 1998, Breast J, V4, P3
[6]   Vacuum-assisted breast biopsy on digital stereotaxic table of nonpalpable lesions non-recognisable by ultrasonography [J].
Apesteguía, L ;
Mellado, M ;
Sáenz, J ;
Cordero, JL ;
Repáraz, B ;
De Miguel, C .
EUROPEAN RADIOLOGY, 2002, 12 (03) :638-645
[7]  
BARRETO V, 1991, EUR J SURG ONCOL, V17, P237
[8]   Comparison of histologic diagnosis between stereotactic core needle biopsy and open surgical biopsy [J].
Bauer, RL ;
Sung, J ;
Eckhert, KH ;
Koul, A ;
Castillo, NB ;
Nemoto, T .
ANNALS OF SURGICAL ONCOLOGY, 1997, 4 (04) :316-320
[9]  
Beck R M, 2000, Swiss Surg, V6, P108, DOI 10.1024/1023-9332.6.3.108
[10]   Stereotactic core biopsy of breast microcalcifications: Comparison of film versus digital mammography, both using an add-on unit [J].
Becker, L ;
Taves, D ;
McCurdy, L ;
Muscedere, G ;
Karlik, S ;
Ward, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (06) :1451-1457