Coronary stent implantation changes 3-D vessel geometry and 3-D shear stress distribution

被引:157
作者
Wentzel, JJ
Whelan, DM
van der Giessen, WJ
van Beusekom, HMM
Andhyiswara, I
Serruys, PW
Slager, CJ
Krams, R [1 ]
机构
[1] Erasmus Univ, Hosp Dijkzigt, Thoraxctr, Rotterdam, Netherlands
[2] Inter Univ Cardiol Inst Netherlands, Utrecht, Netherlands
关键词
stent; coronary artery; shear stress; computational fluid dynamics; 3-D reconstruction;
D O I
10.1016/S0021-9290(00)00066-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Mechanisms of in-stent restenosis are not fully understood. Shear stress is known to play a role in plaque and thrombus formation and is sensitive to changes in regional vessel geometry. Hence, we evaluated the regional changes in 3-D geometry and shear stress induced by stent placement in coronary arteries of pigs. Methods. 3-D reconstruction was performed, applying a combined angiographic and IVUS technique (ANGUS), from seven Wallstents (diameter 3.5 (n = 3) and 5 mm (n = 4)), which were implanted in seven coronary arteries of five pigs. This 3-D geometry was used to calculate locally the curvature, while the shear stress distribution was obtained by computational fluid dynamics. Local changes in shear stress were obtained at the entrance and exit of the stent for baseline (0.65 +/- 0.22 ml/s) and hyperemic flow (2.60 +/- 0.86 ml/s) conditions. Results. after stent implantation, the curvature increased by 121% at the entrance and by 100% at the exit of the stent, resulting in local changes in shear stress. In general, at the entrance of the stent local maxima in shear stress were generated, while at the exit both local maxima and minima in shear stress were observed (p < 0.05). Additionally, the shear stress at the entrance and exit of the stent were correlated with the local curvature (r: 0.30-0.84). Conclusion. Stent implantation changes 3-D vessel geometry in such a way that regions with decreased and increased shear stress occur close to the stent edges. These changes might be related to the asymmetric patterns of in-stent restenosis. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1287 / 1295
页数:9
相关论文
共 25 条
  • [1] Bauters C, 1996, CARDIOVASC RES, V31, P835
  • [2] BRUINING N, 1995, IEEE COMPUTERS CARDI, V95, P633
  • [3] FISCHMAN DL, 1994, NEW ENGL J MED, V331, P539
  • [4] STENT-INDUCED INTIMAL HYPERPLASIA - ARE THERE FUNDAMENTAL DIFFERENCES BETWEEN FLEXIBLE AND RIGID STENT DESIGNS
    FONTAINE, AB
    SPIGOS, DG
    EATON, G
    DOSPASSOS, S
    CHRISTOFORIDIS, G
    KHABIRI, H
    JUNG, S
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (05) : 739 - 744
  • [5] EFFECTS OF ARTERIAL COMPLIANCE AND NON-NEWTONIAN RHEOLOGY ON CORRELATIONS BETWEEN INTIMAL THICKNESS AND WALL SHEAR
    FRIEDMAN, MH
    BARGERON, CB
    DUNCAN, DD
    HUTCHINS, GM
    MARK, FF
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (03): : 317 - 320
  • [6] Laban M, 1995, COMPUT CARDIOL, P325, DOI 10.1109/CIC.1995.482638
  • [7] Leon M B, 1996, Semin Interv Cardiol, V1, P247
  • [8] Li W, 1997, THESIS ERASMUS U ROT
  • [9] Control of endothelial cell gene expression by flow
    Malek, AM
    Izumo, S
    [J]. JOURNAL OF BIOMECHANICS, 1995, 28 (12) : 1515 - +
  • [10] Increased blood flow induces regression of intimal hyperplasia
    Mattsson, EJR
    Kohler, TR
    Vergel, SM
    Clowes, AW
    [J]. ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 1997, 17 (10) : 2245 - 2249