Fibrin-film stenting in a porcine coronary injury model: Efficacy and safety compared with uncoated stents

被引:23
作者
McKenna, CJ
Camrud, AR
Sangiorgi, G
Kwon, HM
Edwards, WD
Holmes, DR
Schwartz, RS
机构
[1] Mayo Clin & Mayo Fdn, Div Cardiovasc Dis, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Div Anat Pathol, Rochester, MN 55905 USA
关键词
D O I
10.1016/S0735-1097(98)00080-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. This study was designed to test the efficacy and safety of a fibrin-film-covered stent compared with that of a bare metal stent in the porcine coronary injury model. Background. Biodegradable stents are a potential method of achieving total lesion coverage and delivering local, lesion-specific drug therapy. Methods. Two coronary arteries in each pig were randomly assigned to deployment of either a fibrin-film or a bare tantalum wire-coil stent. An oversized balloon injury, 1.15 to 1.30 times the reference vessel diameter, was induced in each coronary segment before stenting to simulate angioplasty injury. Thirty pigs were studied: group 1 for 28 days (15 pigs); group 2 for 90 days (5 pigs); group 3 for 6 months (5 pigs); group 4 for 1 year (5 pigs). Results. Two pigs died of occlusion of the bare stent and one of occlusion of the fibrin stent (p > 0.99). There were no significant differences between the fibrin stented and bare-stented coronary segments with regard to arterial injury. In group 1 (28 days, 14 pigs), the mean neointimal thicknesses in the fibrin-stented and bare-stented groups were 0.57 +/- 0.31 and 0.57 +/- 0.27 mm, respectively (p = 0.89). In groups 2 to 4 (90 days, four pigs; 6 months, four pigs; 1 year, five pigs), the mean neointimal thicknesses for fibrin-and bare-stented coronary segments at the times studied were 0.48 +/- 0.26 versus 0.50 +/- 0.22 mm at 90 days; 0.35 +/- 0.04 versus 0.35 +/- 0.16 mm at 6 months; and 0.33 +/- 0.14 versus 0.30 +/- 0.14 mm at 1 year (p = 0.98). Conclusions. Fibrin film stents appear to be an excellent candidate for local drug delivery because they can completely and safely cover the stented coronary segment while degrading slowly over 1 to 3 months. This result is important when compared with the poor results of previous studies of synthetic polymer stents. (C) 1998 by the American College of Cardiology.
引用
收藏
页码:1434 / 1438
页数:5
相关论文
共 27 条
[1]   A TECHNIQUE FOR SPRAY APPLICATION OF FIBRIN GLUE DURING CARDIAC OPERATIONS [J].
BAKER, JW ;
SPOTNITZ, WD ;
NOLAN, SP .
ANNALS OF THORACIC SURGERY, 1987, 43 (05) :564-565
[2]   ARTERIAL INTIMAL HYPERPLASIA AFTER OCCLUSION OF THE ADVENTITIAL VASA VASORUM IN THE PIG [J].
BARKER, SGE ;
TALBERT, A ;
COTTAM, S ;
BASKERVILLE, PA ;
MARTIN, JF .
ARTERIOSCLEROSIS AND THROMBOSIS, 1993, 13 (01) :70-77
[3]  
BOVE JR, 1978, TRANSFUSION, V19, P129
[4]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[5]   Local intraluminal infusion of biodegradable polymeric nanoparticles - A novel approach for prolonged drug delivery after balloon angioplasty [J].
Guzman, LA ;
Labhasetwar, V ;
Song, CX ;
Jang, YS ;
Lincoff, AM ;
Levy, R ;
Topol, EJ .
CIRCULATION, 1996, 94 (06) :1441-1448
[6]   Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study [J].
Hoffmann, R ;
Mintz, GS ;
Dussaillant, GR ;
Popma, JJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Griffin, J ;
Leon, MB .
CIRCULATION, 1996, 94 (06) :1247-1254
[7]   POLYMERIC STENTING IN THE PORCINE CORONARY-ARTERY MODEL - DIFFERENTIAL OUTCOME OF EXOGENOUS FIBRIN SLEEVES VERSUS POLYURETHANE-COATED STENTS [J].
HOLMES, DR ;
CAMRUD, AR ;
JORGENSON, MA ;
EDWARDS, WD ;
SCHWARTZ, RS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (02) :525-531
[8]   CORONARY INTIMAL PROLIFERATION AFTER BALLOON INJURY AND STENTING IN SWINE - AN ANIMAL-MODEL OF RESTENOSIS [J].
KARAS, SP ;
GRAVANIS, MB ;
SANTOIAN, EC ;
ROBINSON, KA ;
ANDERBERG, KA ;
KING, SB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) :467-474
[9]  
McCarthy Patrick M., 1993, Transfusion Medicine Reviews, V7, P173, DOI 10.1016/S0887-7963(93)70136-4
[10]  
Mudra H, 1997, CIRCULATION, V95, P363