Comparison of observer performance in determining the position of endodontic files with physical measures in the evaluation of dental X-ray imaging systems

被引:30
作者
Vandre, RH [1 ]
Pajak, JC [1 ]
Abdel-Nabi, H [1 ]
Farman, TT [1 ]
Farman, AG [1 ]
机构
[1] USA, Med Res & Mat Command, MCMR, PLB, Ft Detrick, MD 21702 USA
关键词
digital radiography; dental; endodontics; technology; radiologic; perception;
D O I
10.1038/sj.dmfr.4600533
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To examine the feasibility of substituting observers determining the accuracy of endodontic measurements for measurements of physical qualities in comparison of digital imaging systems. Methods: Sensors from six digital imaging systems were compared for signal-to-noise ratio (SNR), modulation transfer function (MTF) and detective quantum efficiency (DQE). A total of 45 canals in teeth from human cadavers were instrumented to their apical foramina. Endodontic files, ranging in size from size 8 to size 20, were glued in place at random distances from the apical foramina spanning a range of +/-3 mm. The teeth were imaged with the six digital systems and dental X-ray film. Fifteen dentists independently measured the distance from the end of the file to the epical foramen. Results were expressed as the measurement error. Measurement error was compared to SNR, MTF and DQE for each digital system. Results: CDR (Schick. New York, NY, USA), Digora (Sordex, Helsinki, Finland) and Dexis (Provision Dental Systems, Pale Alto, CA, USA) produced the highest SNR values followed closely by RVG-4 (Trophy, Croissy-Beavborg, France). Sens-A-Ray (Dent-X/Regam Medical Systems, Sundsvall, Sweden), Dexis and the RVG-4 produced the best MTF results. Dexis had the greatest DQE. The mean measurement errors tin mm) were: Film 0.65, Dexis 0.69, CDR 0.71. RVG-3 0.74, Digora 0.89, Sens-A-Ray 0.97, and Visualix-2 (Gendex, Monza, Italy) 0.98. Conclusions: Digital systems closely approximate film in their accuracy when used for endodontic measurement providing that the assessment instruments have similar resolving power. DQE was the best physical predictor of system accuracy when compared with endodontic length measurements. MTF and SNR alone did not accurately predict observer precision.
引用
收藏
页码:216 / 222
页数:7
相关论文
共 11 条
[1]   DQE(F) OF 4 GENERATIONS OF COMPUTED RADIOGRAPHY ACQUISITION DEVICES [J].
DOBBINS, JT ;
ERGUN, DL ;
RUTZ, L ;
HINSHAW, DA ;
BLUME, H ;
CLARK, DC .
MEDICAL PHYSICS, 1995, 22 (10) :1581-1593
[2]   In vivo comparison of Visualix-2 and Ektaspeed Plus in the assessment of periradicular lesion dimensions [J].
Farman, AG ;
Avant, SL ;
Scarfe, WC ;
Farman, TT ;
Green, DB .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1998, 85 (02) :203-209
[3]   Storage-phosphor-based digital mammography using a low-dose x-ray system optimized for screen-film mammography [J].
Jennings, RJ ;
Jafroudi, H ;
Gagne, RM ;
Fewell, TR ;
Quinn, PW ;
Artz, DES ;
Vucich, JJ ;
Freedman, MT ;
Mun, SK .
PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 :220-232
[4]  
JOHNS HE, 1974, PHYSICS RADIOLOGY
[5]   MEDICAL IMAGE PERCEPTION [J].
KUNDEL, HL .
ACADEMIC RADIOLOGY, 1995, 2 :S108-S110
[6]   IMAGE QUALITY OF DIRECT DIGITAL INTRAORAL X-RAY SENSORS IN ASSESSING ROOT-CANAL LENGTH - THE RADIOVISIOGRAPHY, VISUALIX VIXA, SENS-A-RAY, AND FLASH DENT SYSTEMS COMPARED WITH EKTASPEED FILMS [J].
SANDERINK, GCH ;
HUISKENS, R ;
VANDERSTELT, PF ;
WELANDER, US ;
STHEEMAN, SE .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1994, 78 (01) :125-132
[7]   MEASUREMENT ACCURACY - COMPARISON OF 2 INTRAORAL DIGITAL RADIOGRAPHIC SYSTEMS, RADIOVISIOGRAPHY-S AND FLASHDENT, WITH ANALOG FILM [J].
SCARFE, WC ;
NORTON, S ;
FARMAN, AG .
DENTOMAXILLOFACIAL RADIOLOGY, 1995, 24 (04) :215-220
[8]  
Vandre RH, 1996, INT CONGR SER, V1124, P963
[9]  
VANDRE RH, 1997, DENTOMAXILLOFAC RAD, V26, P282
[10]   RESOLUTION AS DEFINED BY LINE SPREAD AND MODULATION TRANSFER-FUNCTIONS FOR 4 DIGITAL INTRAORAL RADIOGRAPHIC SYSTEMS [J].
WELANDER, U ;
MCDAVID, WD ;
SANDERINK, GCH ;
TRONJE, G ;
MORNER, AC ;
DOVE, B .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1994, 78 (01) :109-115