Analysis of wear asymmetry in a series of 94 retrieved polyethylene tibial bearings

被引:15
作者
Currier, JH
Bill, MA
Mayor, MB
机构
[1] Dartmouth Coll, Dartmouth Biomed Engn Ctr, Thayer Sch Engn, Hanover, NH 03755 USA
[2] Dartmouth Hitchcock Med Ctr, Dept Orthoped, Lebanon, NH 03766 USA
关键词
knee arthroplasty; polyethylene wear; retrievals; wear; wear pattern;
D O I
10.1016/j.jbiomech.2004.02.016
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Knee joint kinematics is the focus of a significant amount of experimental study for the purpose of knee prosthesis design and for testing the wear of current and prospective bearing materials. This study reports the wear assessment of a series of 94 explanted tibial bearings of various designs and manufacturers and focuses on the extent to which clinical wear is symmetric in the medial-lateral aspect, or is indicative of a systematic asymmetry that would be informative to the design and testing of knee prostheses or surgical practice. Wear assessment of the series of retrievals indicates that, statistically, there was more clinical wear on the medial side. Patterns of wear varied greatly among individual knees; a majority showed very similar extents of wear on the medial and lateral sides, however there were cases with significantly more wear on one condylar articulation than the other. Evidence of edge loading, where by the femoral component articulates at the margin of the tibial bearing, was common. It was seen most frequently in the central zone of the medial condylar area, and, like the overall wear, edge loading was significantly more frequent on the medial side of bearings. Total bearing wear was seen to generally increase with time over the 208 months of in vivo duration covered by the retrievals in the study. The medial-lateral asymmetry of the wear does not appear to be significantly dependent on duration, however. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:367 / 375
页数:9
相关论文
共 52 条
[1]   Correcting for deformation in skin-based marker systems [J].
Alexander, EJ ;
Andriacchi, TP .
JOURNAL OF BIOMECHANICS, 2001, 34 (03) :355-361
[2]  
ANDRIACCHI TP, 1994, ORTHOP CLIN N AM, V25, P395
[3]  
ANDRIACCHI TP, 2003, CLIN ORTHOP RELAT R, V410, P44
[4]  
*ASTM, 2003, F171500E1 ASTM
[5]  
BANKS SA, 2000, P 67 AAOS ANN M ORL
[6]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[7]  
BELL CJ, 2003, 49 ORTH RES SOC NEW, P1403
[8]   In vivo determination of posterior femoral rollback for subjects having a NexGen posterior cruciate-retaining total knee arthroplasty [J].
Bertin, KC ;
Komistek, RD ;
Dennis, DA ;
Hoff, WA ;
Anderson, DT ;
Langer, T .
JOURNAL OF ARTHROPLASTY, 2002, 17 (08) :1040-1048
[9]   Surface damage in machined ram-extruded and net-shape molded retrieved polyethylene tibial inserts of total knee replacements [J].
Berzins, A ;
Jacobs, JJ ;
Berger, R ;
Ed, C ;
Natarajan, R ;
Andriacchi, T ;
Galante, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (09) :1534-1540
[10]  
BLUNN GW, 1991, CLIN ORTHOP RELAT R, P253