Electrochemical detection in a microfluidic device of oxidative stress generated by macrophage cells

被引:69
作者
Amatore, Christian [1 ]
Arbault, Stephane [1 ]
Chen, Yong [1 ]
Crozatier, Cecile [1 ]
Tapsoba, Issa [1 ]
机构
[1] Univ Paris 06, ENS, CNRS, UMR 8640 Pasteur, F-75231 Paris 05, France
关键词
D O I
10.1039/b611569a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The release of reactive oxygen species (ROS) or reactive nitrogen species (RNS), i.e., the initial phase of oxidative stress, by macrophage cells has been studied by electrochemistry within a microfluidic device. Macrophages were first cultured into a detection chamber containing the three electrodes system and were subsequently stimulated by the microinjection of a calcium ionophore (A23187). Their production of ROS and RNS was then measured by amperometry at the surface of a platinized microelectrode. The fabricated microfluidic device provides an accurate measurement of oxidative release kinetics with an excellent reproducibility. We believe that such a method is simple and versatile for a number of advanced applications based on the detection of biological processes of secretion by a few or even a single living cell.
引用
收藏
页码:233 / 238
页数:6
相关论文
共 30 条
[1]   Monitoring in real time with a microelectrode the release of reactive oxygen and nitrogen species by a single macrophage stimulated by its membrane mechanical depolarization [J].
Amatore, C ;
Arbault, S ;
Bouton, C ;
Coffi, K ;
Drapier, JC ;
Ghandour, H ;
Tong, YH .
CHEMBIOCHEM, 2006, 7 (04) :653-661
[2]   Analysis of individual biochemical events based on artificial synapses using ultramicroelectrodes: cellular oxidative burst [J].
Amatore, C ;
Arbault, S ;
Bruce, D ;
de Oliveira, P ;
Erard, M ;
Vuillaume, M .
FARADAY DISCUSSIONS, 2000, 116 :319-333
[3]   MONITORING AN OXIDATIVE STRESS MECHANISM AT A SINGLE HUMAN FIBROBLAST [J].
ARBAULT, S ;
PANTANO, P ;
JANKOWSKI, JA ;
VUILLAUME, M ;
AMATORE, C .
ANALYTICAL CHEMISTRY, 1995, 67 (19) :3382-3390
[4]   Oxidative stress in cancer prone xeroderma pigmentosum fibroblasts. Real-time and single cell monitoring of superoxide and nitric oxide production with microelectrodes [J].
Arbault, S ;
Sojic, N ;
Bruce, D ;
Amatore, C ;
Sarasin, A ;
Vuillaume, M .
CARCINOGENESIS, 2004, 25 (04) :509-515
[5]   Phenylarsine oxide inhibits ex vivo HIV-1 expression [J].
Arbault, S ;
Edeas, M ;
Legrand-Poels, S ;
Sojic, N ;
Amatore, C ;
Piette, J ;
Best-Belpomme, M ;
Lindenbaum, A ;
Vuillaume, M .
BIOMEDICINE & PHARMACOTHERAPY, 1997, 51 (10) :430-438
[6]   BIOLUMINESCENT MEASUREMENT IN SINGLE CARDIOMYOCYTES OF SUDDEN CYTOSOLIC ATP DEPLETION COINCIDENT WITH RIGOR [J].
BOWERS, KC ;
ALLSHIRE, AP ;
COBBOLD, PH .
JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 1992, 24 (03) :213-218
[7]   Single cell measurements of purine release using a micromachined electroanalytical sensor [J].
Bratten, CDT ;
Cobbold, PH ;
Cooper, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (06) :1164-1170
[8]   Micromachining sensors for electrochemical measurement in subnanoliter volumes [J].
Bratten, CDT ;
Cobbold, PH ;
Cooper, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :253-258
[9]   Quantitative chemical analysis of single cells [J].
Cannon, DM ;
Winograd, N ;
Ewing, AG .
ANNUAL REVIEW OF BIOPHYSICS AND BIOMOLECULAR STRUCTURE, 2000, 29 :239-263
[10]   A Microfabricated Rotary Pump [J].
Chou, Hou-Pu ;
Unger, Marc A. ;
Quake, Stephen R. .
BIOMEDICAL MICRODEVICES, 2001, 3 (04) :323-330