Electrochemical detection in a microfluidic device of oxidative stress generated by macrophage cells

被引:69
作者
Amatore, Christian [1 ]
Arbault, Stephane [1 ]
Chen, Yong [1 ]
Crozatier, Cecile [1 ]
Tapsoba, Issa [1 ]
机构
[1] Univ Paris 06, ENS, CNRS, UMR 8640 Pasteur, F-75231 Paris 05, France
关键词
D O I
10.1039/b611569a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The release of reactive oxygen species (ROS) or reactive nitrogen species (RNS), i.e., the initial phase of oxidative stress, by macrophage cells has been studied by electrochemistry within a microfluidic device. Macrophages were first cultured into a detection chamber containing the three electrodes system and were subsequently stimulated by the microinjection of a calcium ionophore (A23187). Their production of ROS and RNS was then measured by amperometry at the surface of a platinized microelectrode. The fabricated microfluidic device provides an accurate measurement of oxidative release kinetics with an excellent reproducibility. We believe that such a method is simple and versatile for a number of advanced applications based on the detection of biological processes of secretion by a few or even a single living cell.
引用
收藏
页码:233 / 238
页数:6
相关论文
共 30 条
[21]   Microfluidic devices for the high-throughput chemical analysis of cells [J].
McClain, MA ;
Culbertson, CT ;
Jacobson, SC ;
Allbritton, NL ;
Sims, CE ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 2003, 75 (21) :5646-5655
[22]   Cell lysis and protein extraction in a microfluidic device with detection by a fluorogenic enzyme assay [J].
Schilling, EA ;
Kamholz, AE ;
Yager, P .
ANALYTICAL CHEMISTRY, 2002, 74 (08) :1798-1804
[23]   Measurement of intracellular calcium [J].
Takahashi, A ;
Camacho, P ;
Lechleiter, JD ;
Herman, B .
PHYSIOLOGICAL REVIEWS, 1999, 79 (04) :1089-1125
[24]   Spatio-temporal resolution of exocytosis from individual cells [J].
Travis, ER ;
Wightman, RM .
ANNUAL REVIEW OF BIOPHYSICS AND BIOMOLECULAR STRUCTURE, 1998, 27 :77-103
[25]   Monolithic microfabricated valves and pumps by multilayer soft lithography [J].
Unger, MA ;
Chou, HP ;
Thorsen, T ;
Scherer, A ;
Quake, SR .
SCIENCE, 2000, 288 (5463) :113-116
[26]   Microchip device for cell lysis, multiplex PCR amplification, and electrophoretic sizing [J].
Waters, LC ;
Jacobson, SC ;
Kroutchinina, N ;
Khandurina, J ;
Foote, RS ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (01) :158-162
[27]   Microfluidic device for single-cell analysis [J].
Wheeler, AR ;
Throndset, WR ;
Whelan, RJ ;
Leach, AM ;
Zare, RN ;
Liao, YH ;
Farrell, K ;
Manger, ID ;
Daridon, A .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3581-3586
[28]   Integrating advanced functionality in a microfabricated high-throughput fluorescent-activated cell sorter [J].
Wolff, A ;
Perch-Nielsen, IR ;
Larsen, UD ;
Friis, P ;
Goranovic, G ;
Poulsen, CR ;
Kutter, JP ;
Telleman, P .
LAB ON A CHIP, 2003, 3 (01) :22-27
[29]   Amperometric ultramicrosensors for peroxynitrite detection and its application toward single myocardial cells [J].
Xue, J ;
Ying, XY ;
Chen, JS ;
Xian, YH ;
Jin, LT ;
Jin, J .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5313-5321
[30]   Cell docking and on-chip monitoring of cellular reactions with a controlled concentration gradient on a microfluidic device [J].
Yang, MS ;
Li, CW ;
Yang, J .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :3991-4001