Full-field velocity and temperature measurements using magnetic resonance imaging in turbulent complex internal flows

被引:64
作者
Elkins, CJ [1 ]
Markl, M
Iyengar, A
Wicker, R
Eaton, JK
机构
[1] Stanford Univ, Dept Mech Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Lucas MRI S Ctr, Stanford, CA 94305 USA
[3] Univ Texas, Dept Mech & Ind Engn, El Paso, TX 79968 USA
关键词
D O I
10.1016/j.ijheatfluidflow.2004.05.017
中图分类号
O414.1 [热力学];
学科分类号
摘要
Flow and heat transfer in complex internal passages are difficult to predict due to the presence of strong secondary flows and multiple regions of separation. Two methods based on magnetic resonance imaging called 4D magnetic resonance velocimetry (4D-MRV) and thermometry (4D-MRT) are described for measuring the full-field mean velocities and temperatures, respectively, in complex internal passage flows. 4D-MRV measurements are presented for flow through a model of a gas turbine blade internal cooling passage geometry with Re-h = 10,000 and compared to PIV measurements in a highly complex 180degrees bend. Measured three-component velocities provide excellent qualitative and quantitative insight into flow structures throughout the entire flow domain. The velocities agree within +/-10% in magnitude and +/-10degrees in direction in a large portion of the bend which is characterized by turbulent fluctuations as high as 10-20% of the passage inlet bulk velocity. Integrated average flow rates are accurate to 4% throughout the flow domain. Preliminary 4D-MRV/MRT results are presented for heated fully developed turbulent pipe flow at Re-D = 13,000. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:702 / 710
页数:9
相关论文
共 25 条
[1]  
[Anonymous], 1999, MAGNETIC RESONANCE I
[2]   Non-invasive temperature mapping using MRI:: Comparison of two methods based on chemical shift and T1-relaxation [J].
Bertsch, F ;
Mattner, J ;
Stehling, MK ;
Müller-Lisse, U ;
Peller, M ;
Loeffler, R ;
Weber, J ;
Messmer, K ;
Wilmanns, W ;
Issels, R ;
Reiser, M .
MAGNETIC RESONANCE IMAGING, 1998, 16 (04) :393-403
[3]  
Bogren HG, 1999, J MAGN RESON IMAGING, V10, P861, DOI 10.1002/(SICI)1522-2586(199911)10:5<861::AID-JMRI35>3.0.CO
[4]  
2-E
[5]   Simultaneous magnetic resonance phase and magnitude temperature maps in muscle [J].
Cline, HE ;
Hynynen, K ;
Schneider, E ;
Hardy, CJ ;
Maier, SE ;
Watkins, RD ;
Jolesz, FA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) :309-315
[6]   Reynolds number effects in a turbulent pipe flow for low to moderate Re [J].
denToonder, JMJ ;
Nieuwstadt, FTM .
PHYSICS OF FLUIDS, 1997, 9 (11) :3398-3409
[7]   Minimally-invasive ultrasound thermal therapy with MR thermal monitoring and guidance [J].
Diederich, CJ ;
Stafford, RJ ;
Price, RE ;
Nau, WH ;
Tyréus, PD ;
Rivera, B ;
Schomer, D ;
Olsson, L ;
Hazle, J .
THERMAL TREATMENT OF TISSUE: ENERGY DELIVERY AND ASSESSMENT, 2001, 4247 :166-170
[8]   Estimation of relative cardiovascular pressures using time-resolved three-dimensional phase contrast MRI [J].
Ebbers, T ;
Wigström, L ;
Bolger, AF ;
Engvall, J ;
Karlsson, M .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) :872-879
[9]  
Elkins CJ, 2003, EXP FLUIDS, V34, P494, DOI [10.1007/S00348-003-0587-z, 10.1007/S00348-003-0587-Z]
[10]   Nuclear magnetic resonance as a tool to study flow [J].
Fukushima, E .
ANNUAL REVIEW OF FLUID MECHANICS, 1999, 31 :95-123