Peroxidase-glucose oxidase-poly(amphiphilic pyrrole) bioelectrode for selectively mediated amperometric detection of glucose

被引:20
作者
Popescu, IC [1 ]
Cosnier, S
Labbe, P
机构
[1] Univ Babes Bolyai, Dept Phys Chem, RO-3400 Cluj Napoca, Romania
[2] Univ Grenoble 1, Lab Electrochim Organ & Photochim Redox, CNRS, UMR 5630, F-38041 Grenoble 9, France
关键词
horseradish peroxidase; glucose oxidase; polypyrrole; glucose; amperometric biosensor; glucose interferences;
D O I
10.1002/elan.1140091306
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monoenzyme (HRP) and bilayer/monolayer bienzyme (HRP-GOX) bioelectrodes were realized bu the oxidative electropolymerization of amphiphilic pyrrole monomer 1 enzyme(s) mixtures, previously adsorbed on the surface of a glassy carbon electrode. Cyclic voltammetry measurements, carried out on poly 1-HRP modified electrodes showed that the electrocatalytical reduction of H2O2, in the presence of K4Fe(Cn)(6) as mediator, occurs at applied potentials well placed in the optimal potential range for amperometric detection. An optimization study concerning the mediator concentration the amount of the immobilized enzyme(s), the electrode material and the matrix structure (mono-or bilayer) was performed in order to obtain the glucose biosensor, At an applied potential of -0.1 V (vs. SCE), batch amperometric response to H2O2 for the HRP modified electrodes gave a sensitivity of fa. 280 mAM(-1) cm(-2) (up to 0.65 mM). For monolayer biosensor the sensitivity io glucose was ca. 170 mAM(-1) cm(-2) (up to 1.9 mM). The interference of ascorbate, urate and acetaminophen was found almost negligible.
引用
收藏
页码:998 / 1004
页数:7
相关论文
共 70 条
[1]  
BARTLETT PN, 1987, J ELECTROANAL CHEM, V224, P34
[2]   ELECTROCHEMISTRY OF THE POLYPYRROLE GLUCOSE-OXIDASE ELECTRODE [J].
BELANGER, D ;
NADREAU, J ;
FORTIER, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 274 (1-2) :143-155
[3]   PULSED AMPEROMETRIC DETECTION OF GLUCOSE IN BIOLOGICAL-FLUIDS AT A SURFACE-MODIFIED GOLD ELECTRODE [J].
BINDRA, DS ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1989, 61 (22) :2566-2570
[4]   DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING [J].
BINDRA, DS ;
ZHANG, YN ;
WILSON, GS ;
STERNBERG, R ;
THEVENOT, DR ;
MOATTI, D ;
REACH, G .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1692-1696
[5]   ELECTROCATALYTIC REDUCTION OF HYDROGEN-PEROXIDE ON A PALLADIUM-MODIFIED CARBON-PASTE ELECTRODE [J].
CAI, XH ;
KALCHER, K ;
KOLBL, G ;
NEUHOLD, C ;
DIEWALD, W ;
OGOREVC, B .
ELECTROANALYSIS, 1995, 7 (04) :340-345
[6]   INDIUM-TIN OXIDE FILM ELECTRODE AS CATALYTIC AMPEROMETRIC SENSOR FOR HYDROGEN-PEROXIDE [J].
CAI, XH ;
OGOREVC, B ;
TAVCAR, G ;
WANG, J .
ANALYST, 1995, 120 (10) :2579-2583
[7]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[8]   NOVEL ELECTROCHEMICAL DEVICE FOR THE DETECTION OF CHOLESTEROL OR GLUCOSE [J].
CASSIDY, JF ;
CLINTON, C ;
BREEN, W ;
FOSTER, R ;
ODONOGHUE, E .
ANALYST, 1993, 118 (04) :415-418
[9]   INTERFERENCE-FREE GLUCOSE SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN OVEROXIDIZED NONCONDUCTING POLYPYRROLE FILM [J].
CENTONZE, D ;
GUERRIERI, A ;
MALITESTA, C ;
PALMISANO, F ;
ZAMBONIN, PG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (09) :729-733
[10]   ELECTROCHEMICALLY PREPARED GLUCOSE BIOSENSORS - KINETIC AND FARADAIC PROCESSES INVOLVING ASCORBIC-ACID AND ROLE OF THE ELECTROPOLYMERIZED FILM IN PREVENTING ELECTRODE-FOULING [J].
CENTONZE, D ;
GUERRIERI, A ;
PALMISANO, F ;
TORSI, L ;
ZAMBONIN, PG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 349 (07) :497-501