Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment

被引:193
作者
Dada, Tanuj [1 ]
Sihota, Ramanjit [1 ]
Gadia, Ritu [1 ]
Aggarwal, Anand [1 ]
Mandal, Subrata [1 ]
Gupta, Viney [1 ]
机构
[1] All India Inst Med Sci, Dr Rajendra Prasad Ctr Ophthalm Sci, Glaucoma Res Lab, New Delhi 110029, India
关键词
D O I
10.1016/j.jcrs.2007.01.021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare anterior segment parameters using quantitative imaging by anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM). SETTING: Tertiary-care glaucoma research center. METHODS: Sixty-three eyes of 63 subjects had anterior segment evaluation by AS-OCT (Visante-Zeiss) and UBM (Paradigm). Central corneal thickness (CCT), anterior chamber depth (ACD) (measured from the central corneal endothelium to the anterior lens capsule), and the peripheral iridocorneal angles (temporal and nasal) were assessed and compared. RESULTS: There was an excellent correlation between AS-OCT and UBM measurements for the nasal angle (r = 0.84; P <.0001), temporal angle (r = 0.86; P <.0001), ACD (r = 0.97; P <.0001), and CCT (r = 0.91; P <.0001). There was no significant difference (paired t test) between the mean ACD, CCT, and angle parameters measured by AS-OCT or UBM. The mean values of the parameters measured by AS-OCT and UBM were, respectively, as follows: nasal angle, 26.25 degrees +/- 11.0 (SD) and 28.27 +/- 11.3 degrees (P =.3); temporal angle, 25.1 +/- 11.4 degrees and 28.3 +/- 13.5 degrees (P = .15); ACD, 2.85 +/- 0.5 mm and 2.78 +/- 0.5 mm (P = .2); and CCT, 512 +/- 46 mu m and 502 +/- 46 mu m (P =.25). The AS-OCT images showed sharper definition of the scleral spur than the UBM images. CONCLUSION: Anterior segment optical coherence tomography and UBM can both be used for anterior segment measurements and yielded comparable results.
引用
收藏
页码:837 / 840
页数:4
相关论文
共 14 条
[1]  
Buchwald J, 2003, KLIN MONATSBL AUGENH, V220, P822
[2]  
Fujimoto JG, 2002, HANDBOOK OF OPTICAL COHERENCE TOMOGRAPHY, P1
[3]   Anterior chamber width measurement by high speed optical coherence tomography [J].
Goldsmith, JA ;
Li, Y ;
Chalita, MR ;
Westphal, V ;
Patil, CA ;
Rollins, AM ;
Izatt, JA ;
Huang, D .
OPHTHALMOLOGY, 2005, 112 (02) :238-244
[4]   Slit-lamp-adapted optical coherence tomography of the anterior segment [J].
Hoerauf, H ;
Wirbelauer, C ;
Scholz, C ;
Engelhardt, R ;
Koch, P ;
Laqua, H ;
Birngruber, R .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (01) :8-18
[5]  
Ishikawa H, 2000, OPHTHALMIC SURG LAS, V31, P342
[6]   MICROMETER-SCALE RESOLUTION IMAGING OF THE ANTERIOR EYE IN-VIVO WITH OPTICAL COHERENCE TOMOGRAPHY [J].
IZATT, JA ;
HEE, MR ;
SWANSON, EA ;
LIN, CP ;
HUANG, D ;
SCHUMAN, JS ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (12) :1584-1589
[7]   Ultrasound biomicroscopic imaging of the anterior aspect of peripheral choroidal melanomas [J].
Maberly, DAL ;
Pavlin, CJ ;
McGowan, HD ;
Foster, FS ;
Simpson, ER .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 123 (04) :506-514
[8]  
PAVLIN CJ, 1990, OPHTHALMOLOGY, V97, P244
[9]   ULTRASOUND BIOMICROSCOPY OF ANTERIOR SEGMENT STRUCTURES IN NORMAL AND GLAUCOMATOUS EYES [J].
PAVLIN, CJ ;
HARASIEWICZ, K ;
FOSTER, FS .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1992, 113 (04) :381-389
[10]   Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles [J].
Radhakrishnan, S ;
Goldsmith, J ;
Huang, D ;
Westphal, V ;
Dueker, DK ;
Rollins, AM ;
Izatt, JA ;
Smith, SD .
ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (08) :1053-1059