Pitfalls in haemodynamic monitoring based on the arterial pressure waveform

被引:41
作者
Camporota, Luigi [1 ]
Beale, Richard [1 ]
机构
[1] St Thomas Hosp, Guys & St Thomas NHS Fdn Trust, Dept Adult Crit Care, London SE1 7EH, England
来源
CRITICAL CARE | 2010年 / 14卷 / 02期
关键词
CARDIAC-OUTPUT; BLOOD PRESSURE; THERMODILUTION; SYSTEM;
D O I
10.1186/cc8845
中图分类号
R4 [临床医学];
学科分类号
100218 [急诊医学];
摘要
The accuracy of the arterial pressure-based cardiac output FloTrac-Vigileo system remains unacceptably low during haemodynamic instability. Data show that the measurement of cardiac output (CO) is strongly influenced by changes in factors that affect arterial blood pressure (ABP) - for example, vascular tone and compliance and the arterial site - independently of true changes in CO. Although in theory the autocalibration algorithm of FloTrac-Vigileo should adjust for those changes, the model undercompensates (or overcompensates) for prominent increases (or decreases) in vascular tone and compliance, making the system largely dependent on changes in ABP. These limitations make FloTrac-Vigileo accurate in stable haemodynamic conditions only, and until more robust algorithms and further validation studies become available, we should be aware that during haemodynamic instability or in extreme conditions of vasodilation or vasoconstriction, the measured CO may diverge from an independent bolus indicator dilution measurement, particularly if a peripheral artery is used. In these conditions, we advocate the use of transpulmonary indicator dilution via a femoral artery.
引用
收藏
页数:3
相关论文
共 15 条
[1]
Radial to femoral arterial blood pressure differences during liver transplantation [J].
Arnal, D ;
Garutti, I ;
Perez-Peña, J ;
Olmedilla, L ;
Tzenkov, IG .
ANAESTHESIA, 2005, 60 (08) :766-771
[2]
Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery [J].
Biancofiore, G. ;
Critchley, L. A. H. ;
Lee, A. ;
Bindi, L. ;
Bisa, M. ;
Esposito, M. ;
Meacci, L. ;
Mozzo, R. ;
DeSimone, P. ;
Urbani, L. ;
Filipponi, F. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (01) :47-54
[3]
Femoral artery pressures are more reliable than radial artery pressures on initiation of cardiopulmonary bypass [J].
Chauhan, S ;
Saxena, N ;
Mehrotra, S ;
Rao, BH ;
Sahu, M .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2000, 14 (03) :274-276
[4]
Performance of a minimally invasive uncalibrated cardiac output monitoring system (Flotrac™/Vigileo™) in haemodynamically unstable patients [J].
Compton, F. D. ;
Zukunft, B. ;
Hoffmann, C. ;
Zidek, W. ;
Schaefer, J. -H. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 100 (04) :451-456
[5]
Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients [J].
Dorman, T ;
Breslow, MJ ;
Lipsett, PA ;
Rosenberg, JM ;
Balser, JR ;
Almog, Y ;
Rosenfeld, BA .
CRITICAL CARE MEDICINE, 1998, 26 (10) :1646-1649
[6]
Variations in arterial blood pressure are associated with parallel changes in FlowTrac/Vigileo®-derived cardiac output measurements: a prospective comparison study [J].
Eleftheriadis, Savvas ;
Galatoudis, Zisis ;
Didilis, Vasilios ;
Bougioukas, Ioannis ;
Schon, Julika ;
Heinze, Hermann ;
Berger, Klaus-Ulrich ;
Heringlake, Matthias .
CRITICAL CARE, 2009, 13 (06) :R179
[7]
HOFER CK, 2009, J CARDIOTHORAC 0821
[8]
Deep hypothermic circulatory arrest and the femoral-to-radial arterial pressure gradient [J].
Manecke, GR ;
Parimucha, M ;
Stratmann, G ;
Wilson, WC ;
Roth, DM ;
Auger, WR ;
Kerr, KM ;
Jamieson, SW ;
Kapelanski, DP ;
Mitchell, MM .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2004, 18 (02) :175-179
[9]
Cardiac output measurement in patients undergoing liver transplantation:: Pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis [J].
Matthieu, Biais ;
Karine, Nouette-Gaulain ;
Vincent, Cottenceau ;
Alain, Vallet ;
Francois, Cochard Jean ;
Philippe, Revel ;
Francois, Sztark .
ANESTHESIA AND ANALGESIA, 2008, 106 (05) :1480-1486
[10]
RETRACTED: Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery (Retracted Article) [J].
Mayer, J. ;
Boldt, J. ;
Schoellhorn, T. ;
Roehm, K. D. ;
Mengistu, A. M. ;
Suttner, S. .
BRITISH JOURNAL OF ANAESTHESIA, 2007, 98 (02) :176-182