A method for determining multileaf collimator transmission and scatter for dynamic intensity modulated radiotherapy

被引:85
作者
Arnfield, MR [1 ]
Siebers, JV
Kim, JO
Wu, QW
Keall, PJ
Mohan, R
机构
[1] Virginia Commonwealth Univ, Med Coll Virginia, Dept Radiat Oncol, Richmond, VA 23298 USA
[2] McGuire VA Hosp, Richmond, VA 23298 USA
关键词
multileaf collimator; intensity modulated radiotherapy; dosimetry; Monte Carlo method;
D O I
10.1118/1.1312190
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The main purpose of this work is to demonstrate a practical means of determining the leaf transmission and scatter characteristics of a multileaf collimator (MLC) pertinent to the commissioning of dynamic intensity modulated radiotherapy, especially for the sweeping window technique. The data are necessary for the conversion of intensity distributions produced by intensity-modulated radiotherapy optimization systems into trajectories of MLC leaves for dynamic delivery. Measurements are described for two, tungsten alloy MLCs: a Mark II 80-leaf MLC on a Varian 2100C accelerator and a Millenium 120-leaf MLC on a Varian 2100EX accelerator. MLC leakage was measured by film for a series of held sizes. Measured MLC leakage was 1.68% for a 10x10 cm(2) field for both 6 and 18 MV for the 80-leaf MLC. For the 6 MV field, the 1.68% leakage consisted of 1.48% direct transmission and 0.20% leaf scatter. Direct transmission through the 80-leaf MLC, including the rounded leaf tip, was calculated analytically taking into account the detailed leaf geometry and a Monte Carlo-generated energy spectrum of the accelerator. The integrated fluence under the leaf tip was equivalent to an inward shift of 0.06 cm of a hypothetical leaf with a flat, focused tip. Monte Carlo calculations of the dose to phantom beyond a closed 80-leaf MLC showed excellent agreement with the analytic results. The transmission depends on the density of the MLC alloy, which may differ among individual MLCs. Thus, it is important to measure the transmission of any particular MLC. Calculated doses for a series of uniform fields produced by dynamic sweeping windows of various widths agree with measurements within 2%. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)01810-1].
引用
收藏
页码:2231 / 2241
页数:11
相关论文
共 21 条
[1]  
[Anonymous], LA13181
[2]   PEACOCK(TM) - A SYSTEM FOR PLANNING AND ROTATIONAL DELIVERY OF INTENSITY-MODULATED FIELDS [J].
CAROL, MP .
INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1995, 6 (01) :56-61
[3]  
CAROL MP, 1994, USE COMPUTERS RAD TH, P172
[4]   THE GENERATION OF INTENSITY-MODULATED FIELDS FOR CONFORMAL RADIOTHERAPY BY DYNAMIC COLLIMATION [J].
CONVERY, DJ ;
ROSENBLOOM, ME .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (06) :1359-1374
[5]  
Hubbell J. H., TABLES XRAY MASS ATT
[6]   Validation of Monte Carlo generated phase-space descriptions of medical linear accelerators [J].
Libby, B ;
Siebers, J ;
Mohan, R .
MEDICAL PHYSICS, 1999, 26 (08) :1476-1483
[7]   Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy [J].
LoSasso, T ;
Chui, CS ;
Ling, CC .
MEDICAL PHYSICS, 1998, 25 (10) :1919-1927
[8]   TOMOTHERAPY - A NEW CONCEPT FOR THE DELIVERY OF DYNAMIC CONFORMAL RADIOTHERAPY [J].
MACKIE, TR ;
HOLMES, T ;
SWERDLOFF, S ;
RECKWERDT, P ;
DEASY, JO ;
YANG, J ;
PALIWAL, B ;
KINSELLA, T .
MEDICAL PHYSICS, 1993, 20 (06) :1709-1719
[9]  
MACKIE TR, 1994, USE COMPUTERS RAD TH, P176
[10]   The impact of fluctuations in intensity patterns on the number of monitor units and the quality and accuracy of intensity modulated radiotherapy [J].
Mohan, R ;
Arnfield, M ;
Tong, SD ;
Wu, QW ;
Siebers, J .
MEDICAL PHYSICS, 2000, 27 (06) :1226-1237