Response of articular cartilage and subchondral bone to internal fixation devices made of poly-L-lactide:: a histomorphometric and microradiographic study on rabbits

被引:19
作者
Böstman, O [1 ]
Viljanen, J [1 ]
Salminen, S [1 ]
Pihlajamäki, H [1 ]
机构
[1] Helsinki Univ Hosp, Dept Orthopaed & Trauma Surg, FIN-00260 Helsinki, Finland
基金
芬兰科学院;
关键词
articular cartilage tissue response; biodegradable; bone response; internal fixation; polylactide; rabbit;
D O I
10.1016/S0142-9612(00)00123-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To study the tissue response of articular cartilage and subchondral bone to biodegradable fixation devices, pins and rods made of poly-L-lactide with a fibers-in-matrix texture were implanted through the articular surface of the intercondylar portion of the distal rabbit femur. The initial raw material viscosity average molecular weight of the polymer was 660,000. One pin or screw was implanted per animal. The pins were cylindrical and measured 4.5 mm in transverse diameter. The screws had a core diameter of 3.2 mm and an outer diameter of 4.5 mm. At insertion, the implants were cut flush with the articular surface. After follow-up times of 36 and 48 weeks, the specimens were examined histomorphometrically and microradiographically. The intact contralateral femur served as a control for comparison. No signs of erosion or degradation of the polymer could be seen in the specimens. A brim of reparative tissue was formed at the entrance of the implant channel. The width of the reparative tissue from the tissue-implant boundary towards the center of the entrance hole varied greatly between the specimens, from 30 to 950 mu m. In most specimens this bridging tissue consisted of undifferentiated mesenchymal tissue. Only two out of 24 specimens showed a near-normal metachromatic toluidine-blue staining of the matrix. Degenerative chondrocyte clustering occurred in the pre-existing cartilage within a 400 mu m wide zone from the tissue-implant interface into the recipient tissues. Some new-bone formation was seen to envelop the implant in all specimens, but the fractional osteoid formation surface of the trabeculae showed a value significantly higher than that of the intact control side only in the screw-implanted 36-week specimens. Because of the long degradation time of poly-L-lactide, the restoration process of the articular cartilage was slow, and with regard to the quality and quantity of the reparative tissue, very variable. Large implants made of poly-L-lactide may not be suitable for insertion through intra-articular surfaces. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2553 / 2560
页数:8
相关论文
共 53 条
  • [1] Agrawal CM, 1997, J BIOMED MATER RES, V38, P105, DOI 10.1002/(SICI)1097-4636(199722)38:2<105::AID-JBM4>3.0.CO
  • [2] 2-U
  • [3] Absorbable polyglycolide devices in trauma and bone surgery
    Ashammakhi, N
    Rokkanen, P
    [J]. BIOMATERIALS, 1997, 18 (01) : 3 - 9
  • [4] Orthopaedic applications for PLA-PGA biodegradable polymers
    Athanasiou, KA
    Agrawal, CM
    Barber, FA
    Burkhart, SS
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1998, 14 (07) : 726 - 737
  • [5] Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid polyglycolic acid copolymers
    Athanasiou, KA
    Niederauer, GG
    Agrawal, CM
    [J]. BIOMATERIALS, 1996, 17 (02) : 93 - 102
  • [6] FOREIGN-BODY REACTIONS TO RESORBABLE POLY(L-LACTIDE) BONE PLATES AND SCREWS USED FOR THE FIXATION OF UNSTABLE ZYGOMATIC FRACTURES
    BERGSMA, EJ
    ROZEMA, FR
    BOS, RRM
    DEBRUIJN, WC
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (06) : 666 - 670
  • [7] LATE DEGRADATION TISSUE-RESPONSE TO POLY(L-LACTIDE) BONE PLATES AND SCREWS
    BERGSMA, JE
    DEBRUIJN, WC
    ROZEMA, FR
    BOS, RRM
    BOERING, G
    [J]. BIOMATERIALS, 1995, 16 (01) : 25 - 31
  • [8] RESTORATION OF TISSUE-COMPONENTS AFTER INSERTION OF ABSORBABLE FRACTURE FIXATION DEVICES OF POLYGLYCOLIDE THROUGH THE ARTICULAR SURFACE - AN EXPERIMENTAL-STUDY IN THE DISTAL RABBIT FEMUR
    BOSTMAN, O
    PAIVARINTA, U
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (03) : 403 - 411
  • [9] DEGRADATION AND TISSUE REPLACEMENT OF AN ABSORBABLE POLYGLYCOLIDE SCREW IN THE FIXATION OF RABBIT FEMORAL OSTEOTOMIES
    BOSTMAN, O
    PAIVARINTA, U
    PARTIO, E
    VASENIUS, J
    MANNINEN, M
    ROKKANEN, P
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) : 1021 - 1031
  • [10] POLYMERIC DEBRIS FROM ABSORBABLE POLYGLYCOLIDE SCREWS AND PINS - INTRAOSSEOUS MIGRATION STUDIED IN RABBITS
    BOSTMAN, O
    PAIVARINTA, U
    MANNINEN, M
    ROKKANEN, P
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (05): : 555 - 559