Rapid analysis of docetaxel in human plasma by tandem mass spectrometry with on-line sample extraction

被引:32
作者
Grozav, AG
Hutson, TE
Zhou, X
Bukowski, RM
Ganapathi, R
Xu, Y
机构
[1] Cleveland State Univ, Dept Chem, Cleveland, OH 44115 USA
[2] Cleveland Clin Fdn, Clin Pharmacol Lab, Expt Therapeut Program, Taussig Canc Ctr, Cleveland, OH 44195 USA
关键词
docetaxel; Taxotere((R)); tandem mass spectrometry; on-line extraction;
D O I
10.1016/j.jpba.2004.05.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, rapid, and sensitive analytical method for the measurement of docetaxel in human plasma was developed and validated. The method is based on positive electrospray ionization tandem mass spectrometry (ESI+-MS-MS) with on-line sample extraction. It uses paclitaxel as internal standard for calibration. The on-line sample extraction minimizes sample handling and is readily adopted for automation. Quantitation of plasma docetaxel was done by the multiple reaction monitoring (MRM) mode. The method had a linear calibration range of 1.00-3000 ng/mL with a correlation coefficient >0.9999. The limit of quantitation (LOQ) for docetaxel in plasma was 1.00 ng/mL. The on-line extraction recovery of docetaxel was between 86.1-94.7%, with %CV less than or equal to 6.1%. This method has high accuracy (90.1-96.3%), and excellent intra-assay (0.6-3.8%) and inter-assay (2.0-5.7%) precision. Its applicability to clinical samples was demonstrated by measuring patient plasma samples after treatment of weekly docetaxel at 25 mg/m(2) as 60-min infusion. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 131
页数:7
相关论文
共 30 条
[21]   Docetaxel (taxotere): Single agent activity, development of combination treatment and reducing side-effects [J].
Pronk, LC ;
Stoter, G ;
Verweij, J .
CANCER TREATMENT REVIEWS, 1995, 21 (05) :463-478
[22]   STUDIES WITH RP-56976 (TAXOTERE) - A SEMISYNTHETIC ANALOG OF TAXOL [J].
RINGEL, I ;
HORWITZ, SB .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1991, 83 (04) :288-291
[23]   Bio-analysis of docetaxel and hydroxylated metabolites in human plasma by high-performance liquid chromatography and automated solid-phase extraction [J].
Rosing, H ;
Lustig, V ;
Koopman, FP ;
Huinink, WWT ;
Beijnen, JH .
JOURNAL OF CHROMATOGRAPHY B, 1997, 696 (01) :89-98
[24]   A rapid reversed phase high performance liquid chromatographic method for the determination of docetaxel (Taxotere®) in human plasma using a column switching technique [J].
Rouini, MR ;
Lotfolahi, A ;
Stewart, DJ ;
Molepo, JM ;
Shirazi, FH ;
Vergniol, JC ;
Tomiak, E ;
Delorme, F ;
Vernillet, L ;
Giguere, M ;
Goel, R .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (08) :1243-1247
[25]   Phase II study of docetaxel, estramustine, and low-dose hydrocortisone in men with hormone-refractory prostate cancer: A final report of CALGB 9780 [J].
Savarese, DM ;
Halabi, S ;
Hars, V ;
Akerley, WL ;
Taplin, ME ;
Godley, PA ;
Hussain, A ;
Small, EJ ;
Vogelzang, NJ .
JOURNAL OF CLINICAL ONCOLOGY, 2001, 19 (09) :2509-2516
[26]   Second-line chemotherapy for non-small-cell lung cancer with monthly docetaxel and weekly gemcitabine: A phase II trial [J].
Spiridonidis, CH ;
Laufman, LR ;
Carman, L ;
Moore, T ;
Blair, S ;
Jones, J ;
George, C ;
Patel, T ;
Roach, R ;
Rupert, R ;
Zangmeister, J ;
Colborn, D ;
Kuebler, JP .
ANNALS OF ONCOLOGY, 2001, 12 (01) :89-94
[27]   DETERMINATION OF TAXOTERE IN HUMAN PLASMA BY A SEMIAUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD [J].
VERGNIOL, JC ;
BRUNO, R ;
MONTAY, G ;
FRYDMAN, A .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 582 (1-2) :273-278
[28]   Liquid chromatography-mass spectrometry method for the analysis of the anti-cancer agent capecitabine and its nucleoside metabolites in human plasma [J].
Xu, Y ;
Grem, JL .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 783 (01) :273-285
[29]   Measurement of anti-cancer agent methoxyamine in plasma by tandem mass spectrometry with on-line sample extraction [J].
Yang, SM ;
Liu, LL ;
Gerson, SL ;
Xu, Y .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 795 (02) :295-307
[30]   Rapid determination of serum melatonin by ESI-MS-MS with direct sample injection [J].
Yang, SM ;
Zheng, XH ;
Xu, Y ;
Zhou, X .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (03) :781-790