Electromyographic signals during gait: criteria for envelope filtering and number of strides

被引:123
作者
Shiavi, R
Frigo, C
Pedotti, A
机构
[1] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37235 USA
[2] Politecn Milan, Dipartimento Bioengn, I-20133 Milan, Italy
[3] IRCCS, Fdn Pro Juventute, Ctr Bioengn, I-20148 Milan, Italy
基金
美国国家科学基金会;
关键词
electromyography; gait; filter;
D O I
10.1007/BF02510739
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The use of linear envelopes to represent the electromyographic (EMG) measurements obtained during locomotion has become common practice. Guidelines for designing envelope filters and specifying the minimum number of strides needed to produce valid EMG profiles have been developed. Electromyograms from eight major muscles of the lower leg are measured from five normal young adults during self-selected slow, free and fast walking speeds. 30 strides per task are measured. The 'ideal' EMG profile is defined from the ensemble average of the rectified EMG signal. An error measure is defined and used as a criterion to assess the appropriateness of various cut-off frequencies for envelope filters and the number of strides required for establishing a good EMG profile. It is found that between six and ten strides are needed to form a representative profile, and an envelope filter with a minimum cut-off frequency of approximately 9 Hz is necessary.
引用
收藏
页码:171 / 178
页数:8
相关论文
共 18 条
[1]  
[Anonymous], ADAPTABILITY HUMAN G
[2]   QUANTIFICATION OF HUMAN DYNAMIC MUSCLE FATIGUE BY ELECTROMYOGRAPHY AND KINEMATIC PROFILES [J].
ARENDTNIELSEN, L ;
SINKJAER, T .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1991, 1 (01) :1-8
[3]  
ARSENAULT AB, 1986, SCAND J REHABIL MED, V18, P133
[4]   DYNAMIC RELATIONSHIP BETWEEN ISOMETRIC MUSCLE TENSION AND ELECTROMYOGRAM IN MAN [J].
GOTTLIEB, GL ;
AGARWAL, GC .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 30 (03) :345-+
[5]  
Hamming RW, 1983, Digital Filters
[6]   OPTIMALITY CRITERION FOR PROCESSING ELECTROMYOGRAPHIC (EMG) SIGNALS RELATING TO HUMAN LOCOMOTION [J].
HERSHLER, C ;
MILNER, M .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1978, 25 (05) :413-420
[7]   SURFACE EMG SPECTRAL CHANGES WITH MUSCLE LENGTH [J].
INBAR, GF ;
ALLIN, J ;
KRANZ, H .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1987, 25 (06) :683-689
[8]   REPEATABILITY OF PHASIC MUSCLE-ACTIVITY - PERFORMANCE OF SURFACE AND INTRAMUSCULAR WIRE ELECTRODES IN GAIT ANALYSIS [J].
KADABA, MP ;
WOOTTEN, ME ;
GAINEY, J ;
COCHRAN, GVB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1985, 3 (03) :350-359
[9]  
KADEFORS R, 1973, NEW DEV ELECTROMYOGR
[10]   EFFECTS OF ELECTROMYOGRAPHIC PROCESSING METHODS ON COMPUTER-AVERAGED SURFACE ELECTROMYOGRAPHIC PROFILES FOR THE GLUTEUS-MEDIUS MUSCLE [J].
KLEISSEN, RFM .
PHYSICAL THERAPY, 1990, 70 (11) :716-722