Quantitative coronary angiographic and intravascular ultrasound assessment of a new nonarticulated stent: Report from the advanced cardiovascular systems MultiLink stent pilot study

被引:32
作者
Carrozza, JP
Hermiller, JB
Linnemeier, TJ
Popma, JJ
Yock, PG
Roubin, GS
Dean, LS
Kuntz, RE
Robertson, L
Ho, KKL
Cutlip, DE
Baim, DS
机构
[1] Beth Israel Deaconess Med Ctr, Div Cardiovasc, Sect Intervent Cardiol, Boston, MA 02215 USA
[2] St Vincents Hosp, Indiana Heart Inst, Indianapolis, IN USA
[3] Stanford Univ, Med Ctr, Ctr Res Intervent Cardiol, Stanford, CA 94305 USA
[4] Washington Cardiol Ctr, Washington, DC USA
[5] Univ Alabama, Div Cardiol, Birmingham, AL USA
关键词
D O I
10.1016/S0735-1097(97)00426-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The purpose of this study was to evaluate the safety, feasibility, optimal deployment technique and I-year clinical outcome for the Advanced Cardiovascular Systems (ACS) Multilink stent, Background. Optimal stent deployment assessed by quantitative coronary angiography and intravascular ultrasound (IVUS) is associated with improved clinical outcome. Methods. Forty-nine consecutive patients with a discrete stenosis in a native coronary artery 3 to 4 mm in diameter were treated with the new, balloon-expandable ACS MultiLink stent. Stent expansion was assessed in all patients using quantitative coronary angiography and serial IVUS imaging after 8-, 12- and 16-atm inflations., Clinical follow up was obtained at 30 days and 1 gear. Results. All 49 patients had successful placement of a Multilink stent without death, emergency coronary artery bypass graft surgery or Q wave myocardial infarction, After placement of the MultiLink stent, the minimal lumen diameter increased from 1.24 to 2.98 mm (p < 0.001), and diameter stenosis decreased from 61% to 7% (p = 0.001), Minimal lumen cross-sectional area by NUS increased progressively after 8, 12 and 16 atm (5.6 to 6.8 to 7.4 mm(2), respectively, p < 0.001), However, only 61% of stents achieved a lumen/reference area ratio greater than or equal to 70%. No adverse clinical events occurred by 30 days, and by 1 year only one patient (2.0%) required revascularization of the stented artery, Conclusions. Treatment of stenoses in native coronary arteries with the MultiLink stent is associated with a high success rate and a low incidence of adverse events by 1 year, despite the fact that the majority of stents did not meet IVUS-defined criteria for "optimal stenting" derived from first-generation devices. (C) 1998 by the American College of Cardiology.
引用
收藏
页码:50 / 56
页数:7
相关论文
共 14 条
  • [1] CARROZZA JP, 1996, CARDIAC CATHETERIZAT, P617
  • [2] deJaegere P, 1996, J INVASIVE CARDIOL, V8, pE12
  • [3] MULTICENTER INVESTIGATION OF CORONARY STENTING TO TREAT ACUTE OR THREATENED CLOSURE AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - CLINICAL AND ANGIOGRAPHIC OUTCOMES
    GEORGE, BS
    VOORHEES, WD
    ROUBIN, GS
    FEARNOT, NE
    PINKERTON, CA
    RAIZNER, AE
    KING, SB
    HOLMES, DR
    TOPOL, EJ
    KEREIAKES, DJ
    HARTZLER, GO
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (01) : 135 - 143
  • [4] BENEFIT OF INTRACORONARY ULTRASOUND IN THE DEPLOYMENT OF PALMAZ-SCHATZ STENTS
    GOLDBERG, SL
    COLOMBO, A
    NAKAMURA, S
    ALMAGOR, Y
    MAIELLO, L
    TOBIS, JM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (04) : 996 - 1003
  • [5] Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study
    Hoffmann, R
    Mintz, GS
    Dussaillant, GR
    Popma, JJ
    Pichard, AD
    Satler, LF
    Kent, KM
    Griffin, J
    Leon, MB
    [J]. CIRCULATION, 1996, 94 (06) : 1247 - 1254
  • [6] LUMINAL LOSS AND SITE OF RESTENOSIS AFTER PALMAZ-SCHATZ CORONARY STENT IMPLANTATION
    IKARI, Y
    HARA, K
    TAMURA, T
    SAEKI, F
    YAMAGUCHI, T
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (03) : 117 - 120
  • [7] LEON MB, 1996, CIRCULATION, V94, pA685
  • [8] Leon MB, 1994, NEW ENGL J MED, V331, P489
  • [9] MASOTTI M, 1996, CIRCULATION, V94, pA685
  • [10] INTRACORONARY ULTRASOUND OBSERVATIONS DURING STENT IMPLANTATION
    NAKAMURA, S
    COLOMBO, A
    GAGLIONE, A
    ALMAGOR, Y
    GOLDBERG, SL
    MAIELLO, L
    FINCI, L
    TOBIS, JM
    [J]. CIRCULATION, 1994, 89 (05) : 2026 - 2034