Nonlinear coded excitation method for ultrasound contrast imaging

被引:60
作者
Borsboom, JMG
Chin, CT
de Jong, N
机构
[1] Erasmus MC, Dept Cardiol, Thoraxctr, Expt Echocardiog Lab, NL-3000 DR Rotterdam, Netherlands
[2] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
[3] Fdn Fundamental Res Matter, FOM, Utrecht, Netherlands
关键词
ultrasound; coded excitation; chirp; bubbles; contrast agents;
D O I
10.1016/S0301-5629(02)00712-3
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Coded excitation with compression on receive is used in medical ultrasound (US) imaging to increase signal-to-noise ratio (SNR) and penetration depth. We performed a computer simulation study to investigate if chirped pulse excitation can be applied in US contrast agent imaging to increase SNR and contrast-to-tissue ratio (CTR) and, thus, reduce contrast agent destruction and tissue harmonics. A new nonlinear compression technique is proposed that selectively compresses the second harmonic component of the response. We compared a chirp of 9.4-mus duration, 2-MHz centre frequency, 45% relative bandwidth to a Gaussian pulse with equal centre frequency and bandwidth. For peak pressures between 50 and 300 kPa, we found for resonant bubbles an increase in response between 10 and 13 dB. Moreover, the axial resolution after compression was comparable to axial resolution of conventional imaging. This effect was relatively insensitive to peak excitation pressure and was largest for bubbles having resonance frequency around the centre frequency of the excitation. (C) 2003 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:277 / 284
页数:8
相关论文
共 15 条
[1]  
[Anonymous], 1970, RADAR HDB
[2]  
BROCKFISHER G, 2000, 5 HEART CTR EUR S UL, P1
[3]  
BURNS PN, 1992, RADIOLOGY, V185, P142
[4]   HIGHER HARMONICS OF VIBRATING GAS-FILLED MICROSPHERES .1. SIMULATIONS [J].
DEJONG, N ;
CORNET, R ;
LANCEE, CT .
ULTRASONICS, 1994, 32 (06) :447-453
[5]   Influence of bubble size distribution on the echogenicity of ultrasound contrast agents -: A study of SonoVue™ [J].
Gorce, JM ;
Arditi, M ;
Schneider, M .
INVESTIGATIVE RADIOLOGY, 2000, 35 (11) :661-671
[6]   TIME-DOMAIN MODELING OF PULSED FINITE-AMPLITUDE SOUND BEAMS [J].
LEE, YS ;
HAMILTON, MF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 97 (02) :906-917
[7]  
MEDWIN H, 1977, ULTRASONICS, V15, P70
[8]  
Misaridis T., 2001, THESIS TU DENMARK
[9]   CODED EXCITATION SYSTEM FOR IMPROVING THE PENETRATION OF REAL-TIME PHASED-ARRAY IMAGING-SYSTEMS [J].
ODONNELL, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (03) :341-351
[10]  
PRESS WH, 1993, NUMERICAL RECIPIES C