Volume-selective 3D turbo spin echo imaging for vascular wall imaging and distensibility measurement

被引:66
作者
Crowe, LA
Gatehouse, P
Yang, GZ
Mohiaddin, RH
Varghese, A
Charrier, C
Keegan, J
Firmin, DN
机构
[1] Royal Brompton & Harefield NHS Trust, Magnet Resonance Unit, Imperial Coll, London SW3 6NP, England
[2] Univ London Imperial Coll Sci Technol & Med, Visual Image Proc Grp, London, England
[3] Royal Brompton Hosp, London, England
关键词
volume-selective imaging; black-blood MR; distensibility; vessel wall; carotid artery;
D O I
10.1002/jmri.10294
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To use a volume-selective 3D turbo spin echo (TSE) technique to image the carotid artery wall and measure distensibility. Materials and Methods: A high-resolution volume-selective 3D TSE sequence has been developed. Volume selection is accomplished by orthogonal gradients for the 90degrees and 180degrees excitations and allows a 3D volume of vessel wall to be imaged in a relatively short time. The technique has been developed to allow imaging at any defined phase of the cardiac cycle so that the vascular function and distensibility can be studied. Results: Scan efficiency is increased by the reduced phase encode field of view (FOV) (k(y) steps) by the use of selective volume excitation. Significantly more slices (k(z) phase encode steps) for vessel coverage can be acquired with the same scan time as that of the conventional sequence while maintaining signal-to-noise ratio (SNR) levels. The practical value of the technique was demonstrated on 10 normal subjects with high-resolution vessel distensibility measurements of the carotid arteries. Conclusion: A volume-selective TSE method has been used for carotid artery wall imaging and measurement of distensibility in normal subjects. Larger coverage of the vessel, and therefore more information for clinical diagnostics, was achieved with the same overall scan time with an SNR comparable to that of 2D full FOV images.
引用
收藏
页码:572 / 580
页数:9
相关论文
共 34 条
[1]  
Botnar RM, 2000, CIRCULATION, V102, P2582
[2]  
Botnar RM, 2001, MAGNET RESON MED, V46, P848, DOI 10.1002/mrm.1268
[3]   Effects of lipid-lowering by simvastatin on human atherosclerotic lesions - A longitudinal study by high-resolution, noninvasive magnetic resonance imaging [J].
Corti, R ;
Fayad, ZA ;
Fuster, V ;
Worthley, SG ;
Helft, G ;
Chesebro, J ;
Mercuri, M ;
Badimon, JJ .
CIRCULATION, 2001, 104 (03) :249-252
[4]   INNER VOLUME MR IMAGING - TECHNICAL CONCEPTS AND THEIR APPLICATION [J].
FEINBERG, DA ;
HOENNINGER, JC ;
CROOKS, LE ;
KAUFMAN, L ;
WATTS, JC ;
ARAKAWA, M .
RADIOLOGY, 1985, 156 (03) :743-747
[5]   FAST SHORT-TAU INVERSION-RECOVERY MR IMAGING [J].
FLECKENSTEIN, JL ;
ARCHER, BT ;
BARKER, BA ;
VAUGHAN, JT ;
PARKEY, RW ;
PESHOCK, RM .
RADIOLOGY, 1991, 179 (02) :499-504
[6]  
Gatehouse PD, 2001, MAGNET RESON MED, V46, P1031, DOI 10.1002/mrm.1293
[7]   CHARACTERIZATION OF ATHEROSCLEROSIS WITH A 1.5-T IMAGING-SYSTEM [J].
GOLD, GE ;
PAULY, JM ;
GLOVER, GH ;
MORETTO, JC ;
MACOVSKI, A ;
HERFKENS, RJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (02) :399-407
[8]   Visualization of fibrous cap thickness and rupture in human atherosclerotic carotid plaque in vivo with high-resolution magnetic resonance imaging [J].
Hatsukami, TS ;
Ross, R ;
Polissar, NL ;
Yuan, C .
CIRCULATION, 2000, 102 (09) :959-964
[9]   Atherosclerotic aortic component quantification by noninvasive magnetic resonance imaging: An in vivo study in rabbits [J].
Helft, G ;
Worthley, SG ;
Fuster, V ;
Zaman, AG ;
Schechter, C ;
Osende, JI ;
Rodriguez, OJ ;
Fayad, ZA ;
Fallon, JT ;
Badimon, JJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (04) :1149-1154
[10]   NUCLEAR MAGNETIC-RESONANCE IMAGING OF ATHEROSCLEROTIC DISEASE [J].
HERFKENS, RJ ;
HIGGINS, CB ;
HRICAK, H ;
LIPTON, MJ ;
CROOKS, LE ;
SHELDON, PE ;
KAUFMAN, L .
RADIOLOGY, 1983, 148 (01) :161-166