Stability and cause of anxiety in patients with an implantable cardioverter-defibrillator:: A longitudinal two-year follow-up

被引:19
作者
Croessmann, Alexander
Pauli, Paul
Dengler, Wilhelm
Kuehlkamp, Volker
Wiedemann, Georg
机构
[1] Univ Wurzburg, Dept Psychol, D-97070 Wurzburg, Germany
[2] Gen Hosp Freudenstadt, Dept Psychiat Psychotherapy & Psychosomat, Freudenstadt, Germany
[3] Heart Ctr Bodensee, Constance, Germany
[4] Goethe Univ Frankfurt, Dept Psychiat & Psychotherapy, D-6000 Frankfurt, Germany
来源
HEART & LUNG | 2007年 / 36卷 / 02期
关键词
D O I
10.1016/j.hrtlng.2006.08.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: Several investigations have found that anxiety disorders often develop in patients with an implantable cardioverter-defibrillator (ICD). This study investigated the inter- and intraindividual stability of anxiety and its relation to ICD activity in patients with an ICD. METHODS: Changes in the psychopathology of 35 patients with an ICD were assessed at the beginning of the trial period and 2.5 years later. Psychometric measures of anxiety were collected. During this period, shocks and antitachycardia pacing were assessed. RESULTS: Anxiety was found to be interindividually stable. We also found a slight, but statistically significant, reduction in trait anxiety and avoidance behavior over time. Patients who experienced R shocks or antitachycardia pacing did not differ on psychometric or demographic variables from patients without those events. CONCLUSIONS: Anxiety seems to be interindividually stable in patients with an ICD. We found no connection between anxiety and tachycardia episodes in patients with an ICD.
引用
收藏
页码:87 / 95
页数:9
相关论文
共 54 条
[1]  
Alpers G. W., 2001, ANGSTSENSITIVITATS I
[2]  
[Anonymous], 1993, FRAGEBOGEN KORPERBEZ
[3]  
[Anonymous], 1994, BECK DEPRESSION INVE
[4]  
Bardy GH, 2005, NEW ENGL J MED, V352, P2146
[5]   Reliability generalization of scores on the Spielberger state-trait anxiety inventory [J].
Barnes, LLB ;
Harp, D ;
Jung, WS .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 2002, 62 (04) :603-618
[6]   AN INVENTORY FOR MEASURING CLINICAL ANXIETY - PSYCHOMETRIC PROPERTIES [J].
BECK, AT ;
BROWN, G ;
EPSTEIN, N ;
STEER, RA .
JOURNAL OF CONSULTING AND CLINICAL PSYCHOLOGY, 1988, 56 (06) :893-897
[7]   Long-term comparison of the implantable cardioverter defibrillator versus amiodarone - Eleven-year follow-up of a subset of patients in the Canadian Implantable Defibrillator Study (CIDS) [J].
Bokhari, F ;
Newman, D ;
Greene, M ;
Korley, V ;
Mangat, I ;
Dorian, P .
CIRCULATION, 2004, 110 (02) :112-116
[8]   Florid psychopathology in patients receiving shocks from implanted cardioverter-defibrillators [J].
Bourke, JP ;
Turkington, D ;
Thomas, G ;
McComb, JM ;
Tynan, M .
HEART, 1997, 78 (06) :581-583
[9]   The psychosocial impact of the implantable cardioverter defibrillator: A meta-analytic review [J].
Burke, JL ;
Hallas, CN ;
Clark-Carter, D ;
White, D ;
Connelly, D .
BRITISH JOURNAL OF HEALTH PSYCHOLOGY, 2003, 8 :165-178
[10]  
Carr DB, 2005, PROG PAIN RES MANAG, V34, P3