Stability and cause of anxiety in patients with an implantable cardioverter-defibrillator:: A longitudinal two-year follow-up

被引:19
作者
Croessmann, Alexander
Pauli, Paul
Dengler, Wilhelm
Kuehlkamp, Volker
Wiedemann, Georg
机构
[1] Univ Wurzburg, Dept Psychol, D-97070 Wurzburg, Germany
[2] Gen Hosp Freudenstadt, Dept Psychiat Psychotherapy & Psychosomat, Freudenstadt, Germany
[3] Heart Ctr Bodensee, Constance, Germany
[4] Goethe Univ Frankfurt, Dept Psychiat & Psychotherapy, D-6000 Frankfurt, Germany
来源
HEART & LUNG | 2007年 / 36卷 / 02期
关键词
D O I
10.1016/j.hrtlng.2006.08.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: Several investigations have found that anxiety disorders often develop in patients with an implantable cardioverter-defibrillator (ICD). This study investigated the inter- and intraindividual stability of anxiety and its relation to ICD activity in patients with an ICD. METHODS: Changes in the psychopathology of 35 patients with an ICD were assessed at the beginning of the trial period and 2.5 years later. Psychometric measures of anxiety were collected. During this period, shocks and antitachycardia pacing were assessed. RESULTS: Anxiety was found to be interindividually stable. We also found a slight, but statistically significant, reduction in trait anxiety and avoidance behavior over time. Patients who experienced R shocks or antitachycardia pacing did not differ on psychometric or demographic variables from patients without those events. CONCLUSIONS: Anxiety seems to be interindividually stable in patients with an ICD. We found no connection between anxiety and tachycardia episodes in patients with an ICD.
引用
收藏
页码:87 / 95
页数:9
相关论文
共 54 条
[21]   Long-term outcomes of a telephone intervention after an ICD [J].
Dougherty, CM ;
Thompson, EA ;
Lewis, FM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (11) :1157-1167
[22]   Short-term efficacy of a telephone intervention by expert nurses after an implantable cardioverter defibrillator [J].
Dougherty, CM ;
Lewis, FM ;
Thompson, EA ;
Baer, JD ;
Kim, W .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (12) :1594-1602
[23]   PSYCHOLOGICAL REACTIONS AND FAMILY ADJUSTMENT IN SHOCK VERSUS NO SHOCK GROUPS AFTER IMPLANTATION OF INTERNAL CARDIOVERTER-DEFIBRILLATOR [J].
DOUGHERTY, CM .
HEART & LUNG, 1995, 24 (04) :281-291
[24]  
Dunbar S B, 1999, Depress Anxiety, V9, P163, DOI 10.1002/(SICI)1520-6394(1999)9:4<163::AID-DA3>3.0.CO
[25]  
2-B
[26]   GPOWER: A general power analysis program [J].
Erdfelder, E ;
Faul, F ;
Buchner, A .
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 1996, 28 (01) :1-11
[27]  
Fiek M, 1999, Z KARDIOL, V88, P815, DOI 10.1007/s003920050357
[28]  
FOA EB, 1988, PANIC PHOBIAS, V2, P159
[29]   Classic conditioning and dysfunctional cognitions in patients with panic disorder and agoraphobia treated with an implantable cardioverter/defibrillator [J].
Godemann, F ;
Ahrens, B ;
Behrens, S ;
Berthold, R ;
Gandor, C ;
Lampe, F ;
Linden, M .
PSYCHOSOMATIC MEDICINE, 2001, 63 (02) :231-238
[30]   Current status of the implantable cardioverter-defibrillator [J].
Gollob, MH ;
Seger, JJ .
CHEST, 2001, 119 (04) :1210-1221