Evaluation of flow-cytometric three-parameter analysis for EGFR quantification and DNA assessment in human bladder carcinomas

被引:7
作者
Brockhoff, G
Wieland, W
Woelfl, G
Hofstaedter, F
Knuechel, R
机构
[1] Univ Regensburg, Inst Pathol, D-93053 Regensburg, Germany
[2] St Josef Hosp, Dept Urol, Regensburg, Germany
来源
VIRCHOWS ARCHIV-AN INTERNATIONAL JOURNAL OF PATHOLOGY | 1998年 / 432卷 / 01期
关键词
multiparameter flow cytometry; DNA measurements; EGFR-quantification; immunohistochemistry;
D O I
10.1007/s004280050137
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Flow-cytometric multi-parameter staining is an excellent method for defining tumour subpopulations. This provides further understanding of tumour heterogeneity and defines the biological relevance of tumour subpopulations. A method of quantifying the epidermal growth factor receptor (EGFR) in parallel with DNA staining, which was previously established in bladder carcinoma cell lines, was applied to twenty-five biopsies of urothelium and urothelial neoplasms. Uro5, a surface glycoprotein, was used to identify urothelial cells. Objective quantification of receptor content via flow cytometry was achieved with beads of defined numbers of antigen-binding sites, and receptor numbers obtained from urothelial and nonurothelial cells were compared with staining intensity in a three-step immunoperoxidase detection of the EGFR. The data obtained matched the immunohistochemical findings and were more sensitive in the low range (ca. 5x10(3)) of receptors. Parallel definition of the proliferative fraction and DNA-ploidy of tumour cells means that this method satisfies the requirements of objective quantification for oncological diagnosis.
引用
收藏
页码:77 / 84
页数:8
相关论文
共 41 条
  • [1] RETROSPECTIVE STUDY OF PROGNOSTIC IMPORTANCE OF DNA FLOW-CYTOMETRY OF URINARY-BLADDER CARCINOMA
    BLOMJOUS, CEM
    SCHIPPER, NW
    BAAK, JPA
    VANGALEN, EM
    DEVOOGT, HJ
    MEYER, CJLM
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1988, 41 (01) : 21 - 25
  • [2] FLOW CYTOMETRIC DETECTION AND QUANTITATION OF THE EPIDERMAL GROWTH-FACTOR RECEPTOR IN COMPARISON TO SCATCHARD ANALYSIS IN HUMAN BLADDER-CARCINOMA CELL-LINES
    BROCKHOFF, G
    HOFSTAEDTER, F
    KNUECHEL, R
    [J]. CYTOMETRY, 1994, 17 (01): : 75 - 83
  • [3] Brockhoff G, 1996, ANAL CELL PATHOL, V11, P55
  • [4] FLOW CYTOMETRIC METHOD FOR THE MEASUREMENT OF EPIDERMAL GROWTH-FACTOR RECEPTOR AND COMPARISON WITH THE RADIO-LIGAND BINDING ASSAY
    BROTHERICK, I
    LENNARD, TWJ
    WILKINSON, SE
    COOK, S
    ANGUS, B
    SHENTON, BK
    [J]. CYTOMETRY, 1994, 16 (03): : 262 - 269
  • [5] CHIN JL, 1985, CANCER, V56, P1677, DOI 10.1002/1097-0142(19851001)56:7<1677::AID-CNCR2820560734>3.0.CO
  • [6] 2-Y
  • [7] SIMULTANEOUS MEASUREMENT OF 2 CELLULAR ANTIGENS AND DNA USING FLUORESCEIN-ISOTHIOCYANATE, R-PHYCOERYTHRIN, AND PROPIDIUM IODIDE ON A STANDARD FACSCAN
    CORVER, WE
    CORNELISSE, CJ
    FLEUREN, GJ
    [J]. CYTOMETRY, 1994, 15 (02): : 117 - 128
  • [8] FRADET Y, 1986, CANCER RES, V46, P5183
  • [9] GUSTAFSON H, 1985, EUR UROL, V11, P410
  • [10] KIMMIG R, 1994, ANAL CELL PATHOL, V7, P205