Recent advances in enhancing the sensitivity of electrophoresis and electrochromatography in capillaries and microchips

被引:175
作者
Breadmore, Michael C. [1 ]
机构
[1] Univ Tasmania, Sch Chem, Australian Ctr Res Separat Sci, Hobart, Tas 7001, Australia
关键词
extraction; focusing; preconcentration; stacking; sweeping;
D O I
10.1002/elps.200600463
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Poor sensitivity is considered to be one of the major limitations of electrophoretic separation methods, particularly when compared to traditional liquid chromatographic techniques. To address this issue, various in-line preconcentration techniques have been developed over the past 15 years, ranging in power and complexity, and there are now a number of well understood approaches routinely capable of providing a 10 000- to 100 000-fold increase in sensitivity, as well as several that can be pushed above a million. Furthermore, these have been achieved with particularly troublesome and often difficult samples, such as those having high salinity from a biological or environmental origin. This review will discuss the most common methods for improving the sensitivity of CE, CEC and microchip version of these, with particular attention to those approaches developed over the last five years.
引用
收藏
页码:254 / 281
页数:28
相关论文
共 329 条
[71]   Electrokinetic concentration enrichment within a microfluidic device using a hydrogel microplug [J].
Dhopeshwarkar, R ;
Li, SA ;
Crooks, RM .
LAB ON A CHIP, 2005, 5 (10) :1148-1154
[72]  
Fanali S, 2000, HRC-J HIGH RES CHROM, V23, P531
[73]   Preconcentration of proteins on microfluidic devices using porous silica membranes [J].
Foote, RS ;
Khandurina, J ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 2005, 77 (01) :57-63
[74]   Analysis of nitrate in biological fluids by capillary electrophoresis [J].
Friedberg, MA ;
Hinsdale, ME ;
Shihabi, ZK .
JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) :491-496
[75]   Response surface methodology in the development of a stacking-sensitive capillary electrophoresis method for the analysis of tricyclic antidepressants in human serum [J].
Galeano-Díaz, T ;
Acedo-Valenzuela, MI ;
Mora-Diéz, N ;
Silva-Rodríguez, A .
ELECTROPHORESIS, 2005, 26 (18) :3518-3527
[76]  
Gebauer P, 2000, ELECTROPHORESIS, V21, P2797, DOI 10.1002/1522-2683(20000801)21:14<2797::AID-ELPS2797>3.0.CO
[77]  
2-P
[78]   SAMPLE SELF-STACKING IN ZONE ELECTROPHORESIS - THEORETICAL DESCRIPTION OF THE ZONE ELECTROPHORETIC SEPARATION OF MINOR COMPOUNDS IN THE PRESENCE OF BULK AMOUNTS OF A SAMPLE COMPONENT WITH HIGH MOBILITY AND LIKE CHARGE [J].
GEBAUER, P ;
THORMANN, W ;
BOCEK, P .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :47-57
[79]   SAMPLE SELF-STACKING AND SAMPLE STACKING IN ZONE ELECTROPHORESIS WITH MAJOR SAMPLE COMPONENTS OF LIKE CHARGE - GENERAL-MODEL AND SCHEME OF POSSIBLE MODES [J].
GEBAUER, P ;
THORMANN, W ;
BOCEK, P .
ELECTROPHORESIS, 1995, 16 (11) :2039-2050
[80]   pH-mediated acid stacking with reverse pressure for the analysis of cationic pharmaceuticals in capillary electrophoresis [J].
Gillogly, JA ;
Lunte, CE .
ELECTROPHORESIS, 2005, 26 (03) :633-639