C-arm CT with XRIIs and digital flat panels: a review

被引:8
作者
Fahrig, R [1 ]
Ganguly, A [1 ]
Starman, JD [1 ]
Strobel, N [1 ]
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
来源
DEVELOPMENTS IN X-RAY TOMOGRAPHY IV | 2004年 / 5535卷
关键词
XRII; digital flat panel detector; C-arm; conebeam CT; artifacts;
D O I
10.1117/12.561147
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
C-ann CT first emerged as a useful high-contrast imaging modality in the late 1990s, using an XRII as the large area x-ray detector. To date, the C-arm approach to intra-procedural 3D imaging has primarily been used for high-contrast imaging tasks. The emerging goal for these systems is to extend the imaging range into the area of soft-tissue, and it is thought that digital flat-panel detectors may help. Flat panels replace the analog image intensifier, the camera optics, the pickup tube and the analog-to-digital converter with an all-digital detector. Flat panel detectors have a linear response, do not require distortion correction, do not suffer from veiling glare or blooming, and have higher dynamic range that current XRIIs. On the other hand, XRIIs have greater flexibility in FOV, and could support higher frame rates at high resolution, thereby reducing the effects of view aliasing. We have experience with a typical XRII-based C-arm imaging system and a new high-end C-arm equipped with a large flat-panel detector. Initial investigations show that when projection pixel size, acquisition geometry and focal spot size are matched, the flat-panel-based system produces reconstructions with improved MTF, primarily due to the additional interpolation step required for XRII warp correction. Investigations of artifact levels and comparison with in vivo CT images are presented.
引用
收藏
页码:400 / 409
页数:10
相关论文
共 52 条
  • [1] [Anonymous], 2000, COMPUTED TOMOGRAPHY
  • [2] Intracranial aneurysms: Clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment
    Anxionnat, R
    Bracard, S
    Ducrocq, X
    Trousset, Y
    Launay, L
    Kerrien, E
    Braun, M
    Vaillant, R
    Scomazzoni, F
    Lebedinsky, A
    Picard, L
    [J]. RADIOLOGY, 2001, 218 (03) : 799 - 808
  • [3] Comparison of flat-panel detector and image-intensifier detector for cone-beam CT
    Baba, R
    Konno, Y
    Ueda, K
    Ikeda, S
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (03) : 153 - 158
  • [4] ANALYSIS AND CORRECTION OF IMPERFECTIONS IN THE IMAGE INTENSIFIER-TV-DIGITIZER IMAGING CHAIN
    BOONE, JM
    SEIBERT, JA
    BARRETT, WA
    BLOOD, EA
    [J]. MEDICAL PHYSICS, 1991, 18 (02) : 236 - 242
  • [5] Determination of the presampled MTF in computed tomography
    Boone, JM
    [J]. MEDICAL PHYSICS, 2001, 28 (03) : 356 - 360
  • [6] Distortion correction for x-ray image intensifiers: Local unwarping polynomials and RBF neural networks
    Cerveri, P
    Forlani, C
    Borghese, NA
    Ferrigno, G
    [J]. MEDICAL PHYSICS, 2002, 29 (08) : 1759 - 1771
  • [7] Cone-beam CT from width-truncated projections
    Cho, PS
    Rudd, AD
    Johnson, RH
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1996, 20 (01) : 49 - 57
  • [8] Regularization method for scatter-glare correction in fluoroscopic images
    Close, RA
    Shah, KC
    Whiting, JS
    [J]. MEDICAL PHYSICS, 1999, 26 (09) : 1794 - 1801
  • [9] Fahrig R, 1997, AM J NEURORADIOL, V18, P1507
  • [10] Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Correction of image intensifier distortion
    Fahrig, R
    Moreau, M
    Holdsworth, DW
    [J]. MEDICAL PHYSICS, 1997, 24 (07) : 1097 - 1106