Comparison of samples obtained from 3.2% sodium citrate glass and two 3.2% sodium citrate plastic blood collection tubes used in coagulation testing

被引:27
作者
Gosselin, RC
Janatpour, K
Larkin, EC
Lee, YP
Owings, JT
机构
[1] Univ Calif Davis, Med Ctr, Trauma Div, Dept Pathol, Sacramento, CA 95817 USA
[2] Univ Calif Davis, Med Ctr, Trauma Div, Dept Surg, Sacramento, CA 95817 USA
关键词
glass tubes; plastic tubes; coagulation testing;
D O I
10.1309/7V2KP1HP9Q29BMN2
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
We sought to compare coagulation test results obtained from patients using 2 plastic blood collection tubes and the traditional glass blood collection tube. Blood specimens were obtained from 241 patients in 3.2% buffered sodium citrate using standard glass tubes, in 3.2% buffered sodium citrate in plastic tubes, and in 3.2% sodium citrate "sandwich" tubes (plastic within plastic). All samples were obtained and processed contemporaneously and tested for prothrombin time (PT) and activated partial thromboplastin time (aPTT). Residual plasma was frozen at -70degreesC for future testing, including fibrinogen, antithrombin, plasminogen, protein C and protein (functional and antigenic), dilute Russell viper venom time (DRVVT), ristocetin cofactor, factor XIII, D dimer, anti-Xa activity, and prothrombin fragment. Although paired t test analysis revealed statistically significant differences (P < .05) between glass and plastic for PT, aPTT, fibrinogen, protein C (functional and antigenic), functional protein S, DRVVT and confirmation method, antithrombin, and factor-XIII, these diffierences were not considered clinically significant.
引用
收藏
页码:843 / 848
页数:6
相关论文
共 6 条
[1]  
Biron-Andréani C, 2000, THROMB HAEMOSTASIS, V83, P800
[2]   ESTABLISHING A THERAPEUTIC RANGE FOR HEPARIN-THERAPY [J].
BRILLEDWARDS, P ;
GINSBERG, JS ;
JOHNSTON, M ;
HIRSH, J .
ANNALS OF INTERNAL MEDICINE, 1993, 119 (02) :104-109
[3]  
D'Angelo G, 1999, HAEMATOLOGICA, V84, P656
[4]   A comparison of blood collection in glass versus plastic vacutainers on results of esoteric coagulation assays [J].
Flanders, MM ;
Crist, R ;
Rodgers, GM .
LABORATORY MEDICINE, 2003, 34 (10) :732-735
[5]   Laboratory control of oral anticoagulant therapy: preservation of prothrombin time specimens using a polypropylene collection system [J].
Ridyard, J ;
Bhavnani, M ;
Seal, LH .
CLINICAL AND LABORATORY HAEMATOLOGY, 1998, 20 (06) :369-372
[6]   How to evaluate the influence of blood collection systems on the international sensitivity index. Protocol applied to two new evacuated tubes and eight coagulometer/thromboplastin combinations [J].
Tripodi, A ;
Chantarangkul, V ;
Bressi, C ;
Mannucci, PM .
THROMBOSIS RESEARCH, 2002, 108 (01) :85-89