Laboratory calibration and validation of the Biotrainer and Actitrac activity monitors

被引:41
作者
Welk, GJ
Almeida, J
Morss, G
机构
[1] Iowa State Univ, Dept Hlth & Human Performance, Ames, IA 50011 USA
[2] Univ S Carolina, Columbia, SC 29208 USA
[3] Cooper Inst, Dallas, TX USA
关键词
accelerometers; physical activity; energy expenditure; physical activity assessment;
D O I
10.1249/01.MSS.0000069525.56078.22
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: The Biotrainer and Actitrac activity monitors (IM Systems) offer potential research advantages over existing accelerometry-based activity monitors, but they have not been tested under controlled conditions. The purpose of this study was to develop and test laboratory-based prediction equations for both monitors to estimate energy expenditure (EE) for walking/running movements. Methods: Participants in the study wore a Biotramer and Actitrac monitor on both hips and completed three paced bouts on the treadmill (3, 4, and 6 mph for 6 min each). Metabolic data collected using an indirect calorimetry system were used as the criterion measure. Multiple regression techniques were performed to develop prediction equations, and these equations were then applied to data from a separate sample for cross-validation purposes. Reliability was also examined. Results: The correlations between the raw counts from each monitor and the measured metabolic variables ranged from r = 0.74-0.88 for the Biotrainer and from r = 0.81-0.91 for the Actitrac. The equations predicting EE (kcal-min(-1)) from counts yielded strong validation results for both the Biotrainer (R-2 = 0.88, SEE = 1.47) and the Actitrac (R-2 = 0.91, SEE = 1.24). When used on the cross-validation sample, the correlations between measured and predicted EE were r = 0.93 (Biotrainer) and r = 0.94 (Actitrac). Intraclass reliability coefficients computed between the left and right monitors ranged from 0.60 to 0.71 (Biotrainer) and 0.80 to 0.87 (Actitrac). When the equation developed from one side was applied to data from the monitor on the other side, there were no significant differences in predicted and measured EE for most comparisons. Conclusion: The results support the validity of Biotrainer and Actitrac monitors for estimating energy expenditure under controlled conditions.
引用
收藏
页码:1057 / 1064
页数:8
相关论文
共 20 条
  • [1] Validity of four motion sensors in measuring moderate intensity physical activity
    Bassett, DR
    Ainsworth, BE
    Swartz, AM
    Strath, SJ
    O'Brien, WL
    King, GA
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) : S471 - S480
  • [2] Daily physical activity assessment: Comparison between movement registration and doubly labeled water
    Bouten, CVC
    VerboeketVandeVenne, WPHG
    Westerterp, KR
    Verduin, M
    Janssen, JD
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (02) : 1019 - 1026
  • [3] CATALLIER DJ, 2002, PHYSICAL ACTIVITY AS, P93
  • [4] Dale D, 2002, PHYS ACTIVITY ASSESS, P19
  • [5] Calibration of the Computer Science and Applications, Inc. accelerometer
    Freedson, PS
    Melanson, E
    Sirard, J
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1998, 30 (05) : 777 - 781
  • [6] Validity of accelerometry for the assessment of moderate intensity physical activity in the field
    Hendelman, D
    Miller, K
    Bagget, C
    Debold, E
    Freedson, P
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) : S442 - S449
  • [7] PRACTICAL ASSESSMENT OF BODY-COMPOSITION
    JACKSON, AS
    POLLOCK, ML
    [J]. PHYSICIAN AND SPORTSMEDICINE, 1985, 13 (05) : 76 - &
  • [8] The accuracy of the TriTrac-R3D accelerometer to estimate energy expenditure
    Jakicic, JM
    Winters, C
    Lagally, K
    Ho, J
    Robertson, RJ
    Wing, RR
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1999, 31 (05) : 747 - 754
  • [9] JANZ KF, 1994, MED SCI SPORT EXER, V26, P369
  • [10] The reliability, validity, and stability of a measure of physical activity in the elderly
    Kochersberger, G
    McConnell, E
    Kuchibhatla, MN
    Pieper, C
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1996, 77 (08): : 793 - 795