A modified in-tube solid phase microextraction (SPME) technique in conjunction with a high performance liquid chromatography (HPLC) was developed for the trace determination of polycyclic aromatic hydrocarbons (PAHs) in water samples. The extraction device contained a regular HPLC syringe, replacing the metallic needle by two concentric fused silica capillary tubes. The capillary tubes were coated with polydimethylsiloxane (PDMS) as the sorbent and were attached to the syringe by a homemade interface made from polyether ether ketone (PEEK). The sorption of analytes was achieved by frequent withdrawing and ejecting the water sample from/into a vial via the capillary tubes. For the desorption step, an aliquot of organic solvent was withdrawn and subsequently injected directly into the HPLC system. Limits of detection for the elected PAHs were between 0.001 and 0.006 mug L-1 with a RSD of 2.6-6.3%.
引用
收藏
页码:501 / 505
页数:5
相关论文
共 21 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]   Evaluation of polyaniline as a sorbent for SPE of a variety of polar pesticides from water followed by CD-MEKC-DAD [J].
Bagheri, H ;
Saraji, M ;
Barceló, D .
CHROMATOGRAPHIA, 2004, 59 (5-6) :283-289
[3]   Pyrrole-based conductive polymer as the solid-phase extraction medium for the preconcentration of environmental pollutants in water samples followed by gas chromatography with flame ionization and mass spectrometry detection [J].
Bagheri, H ;
Mohammadi, A .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1015 (1-2) :23-30
[4]   Conductive polymers as new media for solid-phase extraction: Isolation of chlorophenols from water sample [J].
Bagheri, H ;
Saraji, M .
JOURNAL OF CHROMATOGRAPHY A, 2003, 986 (01) :111-119
[5]   Solid-phase clean-up in the liquid chromatographic determination of polycyclic aromatic hydrocarbons in edible oils [J].
Barranco, A ;
Alonso-Salces, RM ;
Bakkali, A ;
Berrueta, LA ;
Gallo, B ;
Vicente, F ;
Sarobe, M .
JOURNAL OF CHROMATOGRAPHY A, 2003, 988 (01) :33-40
[6]   DETERMINATION OF POLYCYCLIC AROMATIC-HYDROCARBONS IN SURFACE-WATER BY COLUMN LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION, USING ONLINE MICELLE-MEDIATED SAMPLE PREPARATION [J].
BROUWER, ER ;
HERMANS, ANJ ;
LINGEMAN, H ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1994, 669 (1-2) :45-57
[7]   ANALYSIS OF ENVIRONMENTAL AIR SAMPLES BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHY ION-TRAP MASS-SPECTROMETRY [J].
CHAI, M ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (03) :693-701
[8]   Automated in-tube solid-phase microextraction-high-performance liquid chromatography for carbamate pesticide analysis [J].
Gou, YN ;
Eisert, R ;
Pawliszyn, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 873 (01) :137-147
[9]   Automated in-tube solid-phase microextraction-liquid chromatography-electrospray ionization mass spectrometry for the determination of ranitidine [J].
Kataoka, H ;
Lord, HL ;
Pawliszyn, J .
JOURNAL OF CHROMATOGRAPHY B, 1999, 731 (02) :353-359
[10]   Solid-phase microextraction of phthalates from water [J].
Luks-Betlej, K ;
Popp, P ;
Janoszka, B ;
Paschke, H .
JOURNAL OF CHROMATOGRAPHY A, 2001, 938 (1-2) :93-101