Hemofiltration of recombinant hirudin by different hemodialyzer membranes: Implications for clinical use

被引:21
作者
Benz, Kerstin
Nauck, Matthias A.
Boehler, Joachim
Fischer, Karl-Georg
机构
[1] Univ Klinikum Erlangen, Kinder & Jugendklin, Erlangen, Germany
[2] Univ Klinikum Greifswald, Inst Klin Chem & Lab Med, Greifswald, Germany
[3] Deutsch Klin Diagnost, Wiesbaden, Germany
[4] Univ Freiburg Klinikum, Med Klin, Abt Nephrol & Allgemeinmed, Freiburg, Germany
来源
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY | 2007年 / 2卷 / 03期
关键词
D O I
10.2215/CJN.02550706
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Recombinant hirudin (lepirudin) is a potent direct thrombin inhibitor that is used particularly for treatment of immune-mediated heparin-induced thrombocytopenia. Because hirudin is almost exclusively eliminated by the kidneys, its half-life is markedly prolonged in patients with severe renal insufficiency. Therefore, these patients are at risk for bleeding, particularly because no antidote is available. To use hirudin safely in patients who are on renal replacement therapy, knowledge of hirudin-sieving characteristics of different hemodialyzers is required. Data on this issue are sparse and in part contradictory. Eight different conventional low-flux and high-flux hemodialyzers were tested in an in vitro circuit with ultrafiltrate reinfusion. In each experiment, lepirudin concentration was repetitively measured during 3 h in the prefilter, the postfilter, and the filtration line using a chromogenic assay. On the basis of these data, sieving coefficients were calculated. All high-flux hemodialyzers tested allowed filtration of hirudin yet with marked differences in steady-state sieving (sieving coefficients in whole blood: polysulfone [PS] 0.97 +/- 0.03; polymethylmethacrylate [PMMA] 0.75 +/- 0.02; polyarylethersulfone 0.73 +/- 0.02; polyamide 0.49 +/- 0.02). None of the low-flux hemodialyzer membranes tested (cuprophane, hemophane, PS, and PMMA) showed significant hirudin filtration. Owing to marked differences in hirudin-sieving characteristics, choice of the appropriate hemodialyzer membrane is an important determinant of bleeding risk in dialysis-dependent patients who are treated with hirudin. In case of overdosage or bleeding complications, hemofiltration via PS membranes is recommended to reduce plasma hirudin concentration. Hirudin dosage should be adapted not only to the clinical situation but also to the hirudin-sieving characteristics of the assigned dialyzer.
引用
收藏
页码:470 / 476
页数:7
相关论文
共 26 条
[1]   Coagulation on biomaterials in flowing blood: Some theoretical considerations [J].
Basmadjian, Diran ;
Sefton, Michael V. ;
Baldwin, Susan A. .
1997, Elsevier Science Ltd, Oxford, United Kingdom (18) :1511-1522
[2]   Treatment of hirudin overdosage in a patient with chronic renal failure [J].
Bauersachs, RM ;
Lindhoff-Last, E ;
Ehrly, AM ;
Betz, C ;
Geiger, H ;
Hauser, IA .
THROMBOSIS AND HAEMOSTASIS, 1999, 81 (02) :323-324
[3]   In vitro study of r-hirudin permeability through membranes of different haemodialysers [J].
Bucha, E ;
Kreml, R ;
Nowak, G .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1999, 14 (12) :2922-2926
[4]   HIRUDIN IN HEMODIALYSIS [J].
BUCHA, E ;
MARKWARDT, F ;
NOWAK, G .
THROMBOSIS RESEARCH, 1990, 60 (06) :445-455
[5]  
Eichler P, 2000, BLOOD, V96, P2373
[6]  
*EUR COMM STAND, 1996, 1283 EUR COMM STAND
[7]   Recombinant hirudin (lepirudin) as anticoagulant in intensive care patients treated with continuous hemodialysis [J].
Fischer, KG ;
van de Loo, A ;
Böhler, J .
KIDNEY INTERNATIONAL, 1999, 56 :S46-S50
[8]  
Fischer KG, 2003, THROMB HAEMOSTASIS, V89, P973
[9]   Hirudin in renal insufficiency [J].
Fischer, KG .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2002, 28 (05) :467-482
[10]  