Simultaneous kinetic-spectrophotometric determination of levodopa and benserazide by bi- and three-way partial least squares calibration

被引:102
作者
Coello, J [1 ]
Maspoch, S [1 ]
Villegas, N [1 ]
机构
[1] Univ Autonoma Barcelona, Fac Ciencias, Dept Quim, Uintat Quim Analit, E-08193 Barcelona, Spain
关键词
levodopa; benserazide; simultaneous kinetic determinations; nPLS;
D O I
10.1016/S0039-9140(00)00539-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A procedure for the simultaneous kinetic-spectrophotometric determination of levodopa (I) and benserazide (II), from their oxidation reaction with KIO4 in an acidic medium, is described, Both species instantly oxidize, giving rise to compounds which present maximum values of absorbance close to 400 nm. In the presence of an excess of the oxidizing agent, the levodopa derivative evolves to form the corresponding aminochrome (lambda (m) = 480 nm), while the benserazide derivative decomposes to yield colorless compounds. The appearance of new compounds, with absorption bands in the region of 500-700 nm, is additionally seen upon adding the oxidizing agent to a mixture of I and II. These compounds also evolve decomposing and forming colorless products. In spite of the complexity of the system studied, the calibration by bi-lineal pal tial least squares (PLS) as well as by three-way partial least squares (nPLS) permit the quantification of both analytes with a precision on the order of 0.7% for levodopa and of 1.5% for benserazide. nPLS also allows for the qualitative interpretation of the phenomena which occur. The proposed method is applied to the quantification of I and II in the commercial, pharmaceutical preparation Madopar, using high performance liquid chromatography (HPLC) as the analytical reference technique. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:627 / 637
页数:11
相关论文
共 23 条
  • [1] [Anonymous], 1989, MULTIVARIATE CALIBRA
  • [2] Novel application and comparison of multivariate calibration for the simultaneous determination of Cu, Zn and Mn at trace levels using flow injection diode array spectrophotometry
    Azubel, M
    Fernández, FM
    Tudino, MB
    Troccoli, OE
    [J]. ANALYTICA CHIMICA ACTA, 1999, 398 (01) : 93 - 102
  • [3] Blanco M, 1996, QUIM ANAL, V15, P266
  • [4] PARTIAL LEAST-SQUARES REGRESSION FOR MULTICOMPONENT KINETIC DETERMINATIONS IN LINEAR AND NONLINEAR-SYSTEMS
    BLANCO, M
    COELLO, J
    ITURRIAGA, H
    MASPOCH, S
    REDON, M
    [J]. ANALYTICA CHIMICA ACTA, 1995, 303 (2-3) : 309 - 320
  • [5] Artificial neural networks and partial least squares regression for pseudo-first-order with respect to the reagent multicomponent kinetic-spectrophotometric determinations
    Blanco, M
    Coello, J
    Iturriaga, H
    Maspoch, S
    Redon, M
    Villegas, N
    [J]. ANALYST, 1996, 121 (04) : 395 - 400
  • [6] BLANCO M, IN PRESS
  • [7] Bro R, 1996, J CHEMOMETR, V10, P47, DOI 10.1002/(SICI)1099-128X(199601)10:1<47::AID-CEM400>3.3.CO
  • [8] 2-3
  • [9] CROUCH SR, IN PRESS
  • [10] Multicomponent kinetic determinations using multivariate calibration techniques
    Cullen, TF
    Crouch, SR
    [J]. MIKROCHIMICA ACTA, 1997, 126 (1-2) : 1 - 9