Thin-film microextraction

被引:370
作者
Bruheim, I [1 ]
Liu, XC [1 ]
Pawliszyn, J [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.1021/ac026162q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The properties of a thin sheet of poly(dimethylsiloxane) (PDMS) membrane as an extraction phase were examined and compared to solid-phase microextraction (SPME) PDMS-coated fiber for application to semivolatile analytes in direct and headspace modes. This new PDMS extraction approach showed much higher extraction rates because of the larger surface area to extraction-phase volume ratio of the thin film. Unlike the coated rod formats of SPME using thick coatings, the high extraction rate of the membrane SPME technique allows larger amounts of analytes to be extracted within a short period of time. Therefore, higher extraction efficiency and sensitivity can be achieved without sacrificing analysis time. In direct membrane SPME extraction, a linear relationship was found between the initial rate of extraction and the surface area of the extraction phase. However, for headspace extraction, the rates were somewhat lower because of the resistance to analyte transport at the sample matrix/headspace barrier. It was found that the effect of this barrier could be reduced by increasing either agitation, temperature, or surface area of the sample matrix/headspace interface. A method for the determination of PAHs in spiked lake water samples was developed based on the membrane PDMS extraction coupled with GC/MS. A linearity of 0.9960 and detection limits in the low-ppt level were found. The reproducibility was found to vary from 2.8% to 10.7%.
引用
收藏
页码:1002 / 1010
页数:9
相关论文
共 17 条
  • [1] Sol-gel coating technology for the preparation of solid-phase microextraction fibers of enhanced thermal stability
    Chong, SL
    Wang, DX
    Hayes, JD
    Wilhite, BW
    Malik, A
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (19) : 3889 - 3898
  • [2] Effect of sample volume on quantitative analysis by solid-phase microextraction .1. Theoretical considerations
    Gorecki, T
    Pawliszyn, J
    [J]. ANALYST, 1997, 122 (10) : 1079 - 1086
  • [3] Determination of uptake kinetics (Sampling rates) by lipid-containing semipermeable membrane devices (SPMDs) for polycyclic aromatic hydrocarbons (PAHs) in water
    Huckins, JN
    Petty, JD
    Orazio, CE
    Lebo, JA
    Clark, RC
    Gibson, VL
    Gala, WR
    Echols, KR
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (21) : 3918 - 3923
  • [4] Air sampling with porous solid-phase microextraction fibers
    Koziel, J
    Jia, MY
    Pawliszyn, J
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (21) : 5178 - 5186
  • [5] Solid phase microextraction of PAHs from aqueous samples using fibers coated with HPLC chemically bonded silica stationary phases
    Liu, Y
    Lee, ML
    Hageman, KJ
    Yang, Y
    Hawthorne, SB
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (24) : 5001 - 5005
  • [6] Porous layer solid phase microextraction using silica banded phases
    Liu, Y
    Shen, YF
    Lee, ML
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (02) : 190 - 195
  • [7] Evolution of solid-phase microextraction technology
    Lord, H
    Pawliszyn, J
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 885 (1-2) : 153 - 193
  • [8] Pawliszyn J., 2002, SAMPLING SAMPLE PREP
  • [9] Pawliszyn J., 1999, APPL SOLID PHASE MIC
  • [10] Pawliszyn J., 1997, SOLID PHASE MICROEXT