Initial results with left ventricular pacemaker lead implantation using a preformed "peel-away" guiding sheath and "side-wire" left ventricular pacing lead

被引:11
作者
Walker, S [1 ]
Levy, T [1 ]
Rex, S [1 ]
Paul, V [1 ]
机构
[1] Harefield Hosp, Dept Cardiol, Harefield UB9 6JH, Middx, England
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2000年 / 23卷 / 06期
关键词
D O I
10.1111/j.1540-8159.2000.tb00885.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We report our preliminary experience with the use of preformed "peel-away" guiding sheaths and "side-wire" pacing leads for permanent biventricular pacemaker insertion in 13 patients with heart failure. Three of these patients were undergoing an upgrade of a preexistent VVIR pacing system after prior His ablation for medically refractory atrial fibrillation. Six- of the patients had undergone attempted biventricular pacemaker insertion, but required left ventricular lead repositioning after total implantation failure or late displacement of the lead. The remaining patients were undergoing new system implantation. Target vessel cannulation was achieved in all patients. However, in one patient, diaphragmatic pacing throughout the target vessel length prevented successful implantation. All other implants were ultimately successful (92% success rate). We conclude that device implantation using a preformed sheath and side-wire pacing lead is feasible and may offer significant benefits over implantation with currently available technology.
引用
收藏
页码:985 / 990
页数:6
相关论文
共 9 条
[1]  
Auricchio A, 1999, AM J CARDIOL, V83, p130D
[2]  
Auricchio A, 1999, AM J CARDIOL, V83, p136D
[3]   A method for permanent transvenous left ventricular pacing [J].
Blanc, JJ ;
Benditt, DG ;
Gilard, M ;
Etienne, Y ;
Mansourati, J ;
Lurie, KG .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11) :2021-2024
[4]   Multisite pacing for end-stage heart failure: Early experience [J].
Cazeau, S ;
Ritter, P ;
Lazarus, A ;
Gras, D ;
Backdach, H ;
Mundler, O ;
Mugica, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (11) :1748-1757
[5]   Permanent left ventricular pacing with transvenous leads inserted into the coronary veins [J].
Daubert, JC ;
Ritter, P ;
Le Breton, H ;
Gras, D ;
LeClercq, C ;
Lazarus, A ;
Mugica, J ;
Mabo, P ;
Cazeau, S .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (01) :239-245
[6]   Multisite pacing as a supplemental treatment of congestive heart failure: Preliminary results of the Medtronic Inc. InSync study [J].
Gras, D ;
Mabo, P ;
Tang, T ;
Luttikuis, O ;
Chatoor, R ;
Pedersen, AK ;
Tscheliessnigg, HH ;
Deharo, JC ;
Puglisi, A ;
Silvestre, J ;
Kimber, S ;
Ross, H ;
Ravazzi, A ;
Paul, V ;
Skehan, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11) :2249-2255
[7]   Endocardial biventricular pacing [J].
Jaïs, P ;
Douard, H ;
Shah, DC ;
Barold, S ;
Barat, JL ;
Clémenty, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11) :2128-2131
[8]   Recurrent atrial electrode displacement complicating a single lead VDD pacing system [J].
Walker, BD ;
Thorburn, CW ;
Kuchar, DL .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (11) :1688-1691
[9]   The use of a 'side-wire' permanent transvenous pacing electrode for left ventricular pacing [J].
Walker, S ;
Levy, T ;
Rex, S ;
Paul, VE .
EUROPACE, 1999, 1 (03) :197-200