Coronary arterial stents: Safety and artifacts during MR imaging

被引:105
作者
Hug, J
Nagel, E
Bornstedt, A
Schnackenburg, B
Oswald, H
Fleck, E
机构
[1] Humboldt Univ, Charite, Dept Internal Med & Cardiol, D-13353 Berlin, Germany
[2] Philips Med Syst, Hamburg, Germany
关键词
coronary vessels; MR; stents and prostheses; magnetic resonance (MR); artifact; rapid imaging; safety;
D O I
10.1148/radiology.216.3.r00se03781
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate the safety and imaging artifacts with different coronary arterial stents and magnetic resonance (MR) imaging sequences. MATERIALS AND METHODS: The heating, artifacts, and ferromagnetism with different stents were studied with a 1.5-T MR tomograph with ultrafast gradients by using turbo spin-echo, turbo gradient-echo, and echo-planar imaging sequences. Nineteen stents, which were 8-25 mm in length and 3.0-4.5 mm in diameter, were evaluated. Stent deviation induced by the magnetic field and during MR imaging, migration, and heating caused by the radio-frequency pulses were examined. The size of imaging artifacts was measured with all the stents under standardized conditions and with six stents after their implantation into the coronary arteries of freshly explanted pig hearts. RESULTS: All except two types of stents showed minimal ferromagnetism. No device migration or heating was induced. Turbo spin-echo images had minimal artifacts; larger artifacts were seen on the turbo gradient-echo and echo-planar images. With ultrafast gradients, the artifacts on the echo-planar images were substantially reduced. CONCLUSION: The studied coronary stents were not influenced by heating or motion during 1.5-T MR imaging. Artifact size differed according to the type and size of the stent and the MR imaging sequence used. Thus, patients with these stents can be safely examined.
引用
收藏
页码:781 / 787
页数:7
相关论文
共 40 条
  • [11] ARTIFACTS IN MR IMAGING AFTER SURGICAL INTERVENTION
    HEINDEL, W
    FRIEDMANN, G
    BUNKE, J
    THOMAS, B
    FIRSCHING, R
    ERNESTUS, RI
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (04) : 596 - 599
  • [12] Quantification of in-plane motion of the coronary arteries during the cardiac cycle: Implications for acquisition window duration for MR flow quantification
    Hofman, MBM
    Wickline, SA
    Lorenz, CH
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03): : 568 - 576
  • [13] SAFETY CONSIDERATIONS IN MR IMAGING
    KANAL, E
    SHELLOCK, FG
    TALAGALA, L
    [J]. RADIOLOGY, 1990, 176 (03) : 593 - 606
  • [14] Usefulness of respiratory gated magnetic resonance coronary angiography in assessing narrowings >=50% in diameter native coronary arteries and in aortocoronary bypass conduits
    Kessler, W
    Achenbach, S
    Moshage, W
    Zink, D
    Kroeker, R
    Nitz, W
    Laub, G
    Bachmann, K
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (08) : 989 - 993
  • [15] MIDDLE-EAR PROSTHESIS - SIGNIFICANCE IN MAGNETIC-RESONANCE-IMAGING
    LEON, JA
    GABRIELE, OF
    [J]. MAGNETIC RESONANCE IMAGING, 1987, 5 (05) : 405 - 406
  • [16] Ludeke K M, 1985, Magn Reson Imaging, V3, P329, DOI 10.1016/0730-725X(85)90397-2
  • [17] INTRAUTERINE CONTRACEPTIVE DEVICES - MR IMAGING
    MARK, AS
    HRICAK, H
    [J]. RADIOLOGY, 1987, 162 (02) : 311 - 314
  • [18] FERROMAGNETISM AND MAGNETIC-RESONANCE ARTIFACTS OF PLATINUM EMBOLIZATION MICROCOILS
    MARSHALL, MW
    TEITELBAUM, GP
    KIM, HS
    DEVEIKIS, J
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1991, 14 (03) : 163 - 166
  • [19] Noninvasive diagnosis of ischemia-induced wall motion abnormalities with the use of high-dose dobutamine stress MRI - Comparison with dobutamine stress echocardiography
    Nagel, E
    Lehmkuhl, HB
    Bocksch, W
    Klein, C
    Vogel, U
    Frantz, E
    Ellmer, A
    Dreysse, S
    Fleck, E
    [J]. CIRCULATION, 1999, 99 (06) : 763 - 770
  • [20] POTENTIAL HAZARDS AND ARTIFACTS OF FERROMAGNETIC AND NONFERROMAGNETIC SURGICAL AND DENTAL MATERIALS AND DEVICES IN NUCLEAR MAGNETIC-RESONANCE IMAGING
    NEW, PFJ
    ROSEN, BR
    BRADY, TJ
    BUONANNO, FS
    KISTLER, JP
    BURT, CT
    HINSHAW, WS
    NEWHOUSE, JH
    POHOST, GM
    TAVERAS, JM