Reliability, responsiveness and interpretability of the neck disability index-Dutch version in primary care

被引:27
作者
Ailliet, Luc [1 ,2 ]
Rubinstein, S. M. [1 ,3 ]
de Vet, H. C. W. [1 ,2 ]
van Tulder, M. W. [1 ,3 ]
Terwee, C. B. [1 ,2 ]
机构
[1] Vrije Univ Amsterdam, Med Ctr, EMGO Inst Hlth & Care Res, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Med Ctr, Dept Epidemiol & Biostat, Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Inst Hlth Sci, Fac Earth & Life Sci, Amsterdam, Netherlands
关键词
Neck disability index; Standard error of measurement; Smallest detectable change; Minimal important change; Responsiveness; Interpretability; CLINICALLY IMPORTANT CHANGE; HEALTH-STATUS; QUESTIONNAIRES; PAIN;
D O I
10.1007/s00586-014-3359-y
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
To establish an evidence-based recommendation for the pragmatic use of the Neck Disability Index-Dutch Version (NDI-DV) in primary care based on an assessment of the reliability, the responsiveness, and the interpretability of the NDI-DV. At baseline, the NDI-DV was completed by 337 patients with neck pain presenting to 97 chiropractic clinics in Belgium and the Netherlands. Three months after inclusion, 265 patients provided data to assess the responsiveness and interpretability. Reliability was assessed in 155 patients (retested after 10 days) by calculating the intra-class correlation coefficient for agreement (ICCagreement) and the measurement error (standard error of measurement, SEM), the latter resulting in the smallest detectable change (SDC). The minimal important change (MIC) was assessed by the anchor-based MIC distribution using self-reported perceived recovery as anchor. We tested interpretability by relating SDC to MIC. The ICCagreement was 0.88. The SEMagreement was 1.95 resulting in a SDC of 5.40. The NDI-DV appeared to be responsive, being able to distinguish improved from stable patients with an area under the curve of 0.85. The MIC was 4.50. The NDI-DV has good reliability and responsiveness and may be used in clinical practice in Belgium and the Netherlands. A change score of 5 is important for patients, but has a 7 % chance to be due to measurement error.
引用
收藏
页码:88 / 93
页数:6
相关论文
共 22 条
[1]
[Anonymous], 2018, Measurement in Medicine
[2]
Changes to the subscales of two vision-related quality of life questionnaires are proposed [J].
de Boer, MR ;
de Vet, HCW ;
Terwee, CB ;
Moll, AC ;
Völker-Dieben, HJM ;
van Rens, GHMB .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2005, 58 (12) :1260-1268
[3]
Minimally important change determined by a visual method integrating an anchor-based and a distribution-based approach [J].
de Vet, Henrica C. W. ;
Ostelo, Raymond W. J. G. ;
Terwee, Caroline B. ;
van der Roer, Nicole ;
Knol, Dirk L. ;
Beckerman, Heleen ;
Boers, Maarten ;
Bouter, Lex M. .
QUALITY OF LIFE RESEARCH, 2007, 16 (01) :131-142
[4]
When to use agreement versus reliability measures [J].
de Vet, Henrica C. W. ;
Terwee, Caroline B. ;
Knol, Dirk L. ;
Bouter, Lex M. .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2006, 59 (10) :1033-1039
[5]
THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[6]
Detecting relevant changes and responsiveness of Neck Pain and Disability Scale and Neck Disability Index [J].
Jorritsma, Wim ;
Dijkstra, Pieter U. ;
de Vries, Grietje E. ;
Geertzen, Jan H. B. ;
Reneman, Michiel F. .
EUROPEAN SPINE JOURNAL, 2012, 21 (12) :2550-2557
[7]
Neck Pain and Disability Scale and Neck Disability Index: validity of Dutch language versions [J].
Jorritsma, Wim ;
de Vries, Grietje E. ;
Dijkstra, Pieter U. ;
Geertzen, Jan H. B. ;
Reneman, Michiel F. .
EUROPEAN SPINE JOURNAL, 2012, 21 (01) :93-100
[8]
Koke AJA, 1996, MEETINSTRUMENTEN C 1, P94
[9]
Measurement Properties of the Neck Disability Index: A Systematic Review [J].
MacDermid, Joy C. ;
Walton, David M. ;
Avery, Sarah ;
Blanchard, Alanna ;
Etruw, Evelyn ;
McAlpine, Cheryl ;
Goldsmith, Charlie H. .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2009, 39 (05) :400-417
[10]
INDIVIDUAL-PATIENT MONITORING IN CLINICAL-PRACTICE - ARE AVAILABLE HEALTH-STATUS SURVEYS ADEQUATE [J].
MCHORNEY, CA ;
TARLOV, AR .
QUALITY OF LIFE RESEARCH, 1995, 4 (04) :293-307