CT-based attenuation correction in the calculation of semi-quantitative indices of [18F]FDG uptake in PET

被引:105
作者
Visvikis, D
Costa, DC
Croasdale, I
Lonn, AHR
Bomanji, J
Gacinovic, S
Ell, PJ
机构
[1] UCL Royal Free & Univ Coll, Sch Med, Inst Nucl Med, Middlesex Hosp, London W1T 3AA, England
[2] GE Med Syst, Slough, Berks, England
关键词
PET/CT; attenuation correction; standardised uptake values;
D O I
10.1007/s00259-002-1070-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The introduction of combined PET/CT systems has a number of advantages, including the utilisation of CT images for PET attenuation correction (AC). The potential advantage compared with existing methodology is less noisy transmission maps within shorter times of acquisition. The objective of our investigation was to assess the accuracy of CT attenuation correction (CTAC) and to study resulting bias and signal to noise ratio (SNR) in image-derived semi-quantitative uptake indices. A combined PET/CT system (GE Discovery LS) was used. Different size phantoms containing variable density components were used to assess the inherent accuracy of a bilinear transformation in the conversion of CT images to 511 keV attenuation maps. This was followed by a phantom study simulating tumour imaging conditions, with a tumour to background ratio of 5:1. An additional variable was the inclusion of contrast agent at different concentration levels. A CT scan was carried out followed by 5 min emission with 1-h and 3-min transmission frames. Clinical data were acquired in 50 patients, who had a CT scan under normal breathing conditions (CTAC(nb)) or under breath-hold with inspiration (CTAC(insp)) or expiration (CTAC(exp)), followed by a PET scan of 5 and 3 min per bed position for the emission and transmission scans respectively. Phantom and patient studies were reconstructed using segmented AC (SAC) and CTAC. In addition, measured AC (MAC) was performed for the phantom study using the I-h transmission frame. Comparing the attenuation coefficients obtained using the CT- and the rod source-based attenuation maps, differences of 3% and <6% were recorded before and after segmentation of the measured transmission maps. Differences of up to 6% and 8% were found in the average count density (SUVavg) between the phantom images reconstructed with MAC and those reconstructed with CTAC and SAC respectively. In the case of CTAC, the difference increased up to 27% with the presence of contrast agent. The presence of metallic implants led to underestimation in the surrounding SUVavg and increasing non-uniformity in the proximity of the implant. The patient study revealed no statistically significant differences in the SUVavg between either CTAC(nb) or CTAC(exp) and SAC-reconstructed images. The larger differences were recorded in the lung. Both the phantom and the patient studies revealed an average increase of similar to25% in the SNR for the CTAC-reconstructed emission images compared with the SAC-reconstructed images. In conclusion, CTACnb or CTACexp is a viable alternative to SAC for whole-body studies. With CTAC, careful consideration should be given to interpretation of images and use of SUVs in the presence of oral contrast and in the proximity of metallic implants.
引用
收藏
页码:344 / 353
页数:10
相关论文
共 20 条
  • [1] An automatic classification technique for attenuation correction in positron emission tomography
    Bettinardi, V
    Pagani, E
    Gilardi, MC
    Landoni, C
    Riddell, C
    Rizzo, G
    Castiglioni, I
    Belluzzo, D
    Lucignani, G
    Schubert, S
    Fazio, F
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (05) : 447 - 458
  • [2] Clinical role of positron emission tomography in oncology
    Bomanji, J. B.
    Costa, D. C.
    Ell, P. J.
    [J]. LANCET ONCOLOGY, 2001, 2 (03) : 157 - 164
  • [3] PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients
    Burger, C
    Goerres, G
    Schoenes, S
    Buck, A
    Lonn, AHR
    von Schulthess, GK
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (07) : 922 - 927
  • [4] Gambhir SS, 2001, J NUCL MED, V42, p1S
  • [5] PET-CT image co-registration in the thorax: influence of respiration
    Goerres, GW
    Kamel, E
    Heidelberg, TNH
    Schwitter, MR
    Burger, C
    von Schulthess, GK
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (03) : 351 - 360
  • [6] DETECT - Dual energy transmission estimation CT - for improved attenuation correction in SPECT and PET
    Guy, MJ
    Castellano-Smith, IA
    Flower, MA
    Flux, GD
    Ott, RJ
    Visvikis, D
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1261 - 1267
  • [7] JORDAN K, IEC EMISSION PHANTOM
  • [8] Attenuation correction for a combined 3D PET/CT scanner
    Kinahan, PE
    Townsend, DW
    Beyer, T
    Sashin, D
    [J]. MEDICAL PHYSICS, 1998, 25 (10) : 2046 - 2053
  • [9] MEIKLE SR, 1993, J NUCL MED, V34, P143
  • [10] Nakamoto Y, 2002, J NUCL MED, V43, P1137