Precision and accuracy of dual-energy X-ray absorptiometry for determining in vivo body composition of mice

被引:244
作者
Nagy, TR [1 ]
Clair, AL [1 ]
机构
[1] Univ Alabama, Dept Nutr Sci, Div Physiol & Metab, Birmingham, AL 35294 USA
来源
OBESITY RESEARCH | 2000年 / 8卷 / 05期
关键词
dual-energy X-ray absorptiometry; DXA; bone mineral density; fat mass;
D O I
10.1038/oby.2000.47
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the precision and accuracy of dual-energy X-ray absorptiometry (DXA) for the measurement of total-bone mineral density (TBMD), total-body bone mineral (TBBM), fat mass (FM), and bone-free lean tissue mass (LTM) in mice. Research Methods and Procedures: Twenty-five male C57BL/6J mice (6 to 11 weeks old; 19 to 29 g) were anesthetized and scanned three times (with repositioning between scans) using a peripheral densitometer (Lunar PIXImus). Gravimetric and chemical extraction techniques (Soxhlet) were used as the criterion method for the determination of body composition; ash content was determined by burning at 600 degrees C for 8 hours. Results: The mean intraindividual coefficients of variation (CV) for the repeated DXA analyses were: TBMD, 0.84%; TBBM, 1.60%; FM, 2.20%; and LTM, 0.86%. Accuracy was determined by comparing the DXA-derived data from the first scan with the chemical carcass analysis data. DXA accurately measured bone ash content (p = 0.942), underestimated LTM (0.59 +/- 0.05g, p < 0.001), and overestimated FM (2.19 +/- 0.06g, p < 0.001). Thus, DXA estimated 100% of bone ash content, 97% of carcass LTM, and 209% of carcass FM. DXA-derived values were then used to predict chemical values of FM and LTM. Chemically extracted FM was best predicted by DXA FM and DXA LTM [FM = -0.50 + 1.09(DXA FM) - 0.11(DXA LTM), model r(3) = 0.86, root mean square error (RMSE) = 0.233 g] and chemically determined LTM by DXA LTM [LTM = -0.14 + 1.04(DXA LTM), r(2) = 0.99, RMSE = 0.238 g]. Discussion: These data show that the precision of DXA for measuring TBMD, TBBM, FM, and LTM in mice ranges from a low of 0.84% to a high of 2.20% (CV). DXA accurately measured bone ash content but overestimated carcass FM and underestimated LTM. However, because of the close relationship between DXA-derived data and chemical carcass analysis for FM and LTM, prediction equations can be derived to more accurately predict body composition.
引用
收藏
页码:392 / 398
页数:7
相关论文
共 14 条
[1]  
[Anonymous], AM J PHYSIOL
[2]   Evaluation of dual-energy X-ray absorptiometry for body-composition assessment in rats [J].
Bertin, E ;
Ruiz, JC ;
Mourot, J ;
Peiniau, P ;
Portha, B .
JOURNAL OF NUTRITION, 1998, 128 (09) :1550-1554
[3]   Improvement in the accuracy of dual energy X-ray absorptiometry for whole body and regional analysis of body composition: Validation using piglets and methodologic considerations in infants [J].
Brunton, JA ;
Weiler, HA ;
Atkinson, SA .
PEDIATRIC RESEARCH, 1997, 41 (04) :590-596
[4]   Total body lipid and triglyceride response to energy deficit: relevance to body composition models [J].
Comizio, R ;
Pietrobelli, A ;
Tan, YX ;
Wang, ZM ;
Withers, RT ;
Heymsfield, SB ;
Boozer, CN .
AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 1998, 274 (05) :E860-E866
[5]   THE EFFECT OF APPARATUS, EXTRACTION TIME, AND SOLVENT TYPE ON LIPID EXTRACTIONS OF SNOW GEESE [J].
DOBUSH, GR ;
ANKNEY, CD ;
KREMENTZ, DG .
CANADIAN JOURNAL OF ZOOLOGY-REVUE CANADIENNE DE ZOOLOGIE, 1985, 63 (08) :1917-1920
[6]   The use of dual-energy x-ray absorptiometry in animals [J].
Grier, SJ ;
Turner, AS ;
Alvis, MR .
INVESTIGATIVE RADIOLOGY, 1996, 31 (01) :50-62
[7]   Dual-energy X-ray absorptiometry for the measurement of gross body composition in rats [J].
Jebb, SA ;
Garland, SW ;
Jennings, G ;
Elia, M .
BRITISH JOURNAL OF NUTRITION, 1996, 75 (06) :803-809
[8]   Quantitative trait loci affecting peak bone mineral density in mice [J].
Klein, RF ;
Mitchell, SR ;
Phillips, TJ ;
Belknap, JK ;
Orwoll, ES .
JOURNAL OF BONE AND MINERAL RESEARCH, 1998, 13 (11) :1648-1656
[9]  
Lohman TG, 1996, HUMAN BODY COMPOSITI, P63
[10]   Precision and accuracy of total body bone mass and body composition measurements in the rat using x-ray-based dual photon absorptiometry [J].
Makan, S ;
Bayley, HS ;
Webber, CE .
CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 1997, 75 (10-11) :1257-1261