Precision and accuracy of total body bone mass and body composition measurements in the rat using x-ray-based dual photon absorptiometry

被引:24
作者
Makan, S
Bayley, HS
Webber, CE
机构
[1] Hamilton Hlth Sci Corp, Dept Nucl Med, Hamilton, ON L8N 3Z5, Canada
[2] Univ Guelph, Dept Human Biol & Nutr Sci, Guelph, ON N1G 2W1, Canada
关键词
dual photon absorptiometry; rats; body composition; bone mass; accuracy; precision;
D O I
10.1139/cjpp-75-10-11-1257
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Lean body mass (LBM), total body bone mineral mass (BMC), total body bone areal density (BMD), and body fat mass (FM) were measured in rats by dual photon absorptiometry (DXA), using two different instruments. The coefficients of variation for repeated measurements of LBM and FM were about 0.4 and 2.5%, respectively, over an animal body weight range of 150 to 600 g. For BMC and BMD, the coefficients of variation were less than 2%. The correlation coefficients for LBM, FM, BMC, and BMD measured on the two densitometers were all greater than 0.94. The slope of the regression line relating LBM measured by DXA and LBM measured by carcass analysis was 0.999, and the correlation coefficient was 0.99. For FM the slope was 1.05, and the correlation coefficient was 0.98. BMC measures by DXA were falsely low in small animals. For larger animals, the correlation between BMC and ash weight was 0.93, but the slope of the regression line was 0.78. DXA measures of LBM and FM were accurate and reproducible for rats weighing between 150 and 600 g. There was a size-dependent error in BMC, which will be significant in longitudinal measurements of bone mass.
引用
收藏
页码:1257 / 1261
页数:5
相关论文
共 7 条
[1]   VALIDATION AND APPLICATION OF DUAL-ENERGY X-RAY ABSORPTIOMETRY TO MEASURE BONE MASS AND BODY-COMPOSITION IN SMALL INFANTS [J].
BRUNTON, JA ;
BAYLEY, HS ;
ATKINSON, SA .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 58 (06) :839-845
[2]   DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR MEASURING TOTAL BONE-MINERAL CONTENT IN THE RAT - STUDY OF ACCURACY AND PRECISION [J].
CASEZ, JP ;
MUEHLBAUER, RC ;
LIPPUNER, K ;
KELLY, T ;
FLEISCH, H ;
JAEGER, P .
BONE AND MINERAL, 1994, 26 (01) :61-68
[3]   PRECISION AND ACCURACY FOR RAT WHOLE-BODY AND FEMUR BONE-MINERAL DETERMINATION WITH DUAL X-RAY ABSORPTIOMETRY [J].
HAGIWARA, S ;
LANE, N ;
ENGELKE, K ;
SEBASTIAN, A ;
KIMMEL, DB ;
GENANT, HK .
BONE AND MINERAL, 1993, 22 (01) :57-68
[4]  
LI XJ, 1991, CELLS MATERIALS S, V1, P25
[5]   DXA FOR BONE-DENSITY MEASUREMENT IN SMALL RATS WEIGHING 150-250 GRAMS [J].
LU, PW ;
BRIODY, JN ;
HOWMANGILES, R ;
TRUBE, A ;
COWELL, CT .
BONE, 1994, 15 (02) :199-202
[6]   EFFECTS OF CASTRATION ON THE BONE-STRUCTURE OF MALE-RATS - A MODEL OF OSTEOPOROSIS [J].
WINK, CS ;
FELTS, WJL .
CALCIFIED TISSUE INTERNATIONAL, 1980, 32 (01) :77-82
[7]  
Wronski TJ., 1992, CELLS MAT, V1, P69