A tensor-based measure for estimating blood damage

被引:102
作者
Arora, D
Behr, M [1 ]
Pasquali, M
机构
[1] Tech Univ Munich, Lehrstuhl Numer Mech, D-85747 Garching, Germany
[2] Rice Univ, Dept Mech Engn & Mat Sci, Houston, TX 77251 USA
[3] Rice Univ, Comp & Informat Technol Inst, Houston, TX 77251 USA
[4] Rice Univ, Dept Chem Engn, Houston, TX 77251 USA
关键词
ventricular assist device; computational fluid dynamics; red blood cell; hemolysis; droplet deformation;
D O I
10.1111/j.1525-1594.2004.00072.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Implantable ventricular assist devices give hope of a permanent clinical solution to heart failure. These devices, both pulsatile- and continuous-flow, are presently used as medium-term bridge to heart transplant or recovery. While long-term use of continuous-flow axial and centrifugal pumps is being explored, the excessive level of blood damage in these devices has emerged as a design challenge. Blood damage depends both on shear stress and exposure time, and device designers have relied traditionally on global space- and time-averaged estimates from experimental studies to make design decisions. Measuring distributions of shear stress levels and the blood cell's exposure to these conditions in complex rotary pump flow is difficult. On the other hand, computational fluid dynamics (CFD) is now being used as a tool for designing viable devices, offering more detailed information about the flow field. A tensor-based blood damage model for CFD analysis is proposed here. The model estimates the time- and space-dependent strain experienced by individual blood cells and correlates it to blood damage data from steady shear flow experiments. The blood cells are modeled as deforming droplets and their deformation is tracked along the pathlines of a computed flow. The model predicts that blood cells in a rapidly fluctuating shear flow can sustain high shear stress levels for very short exposure time without deforming considerably. In the context of mechanical modeling of the implantable Gyro blood pump being developed at Baylor College of Medicine, this suggests that blood cells traversing regions of highly fluctuating shear stress rapidly may not hemolyze significantly.
引用
收藏
页码:1002 / 1015
页数:14
相关论文
共 44 条
[1]   Blood flow in a continuous flow ventricular assist device [J].
Allaire, PE ;
Wood, HG ;
Awad, RS ;
Olsen, DB .
ARTIFICIAL ORGANS, 1999, 23 (08) :769-773
[2]   Computational flow study of the continuous flow ventricular assist device, prototype number 3 blood pump [J].
Anderson, JB ;
Wood, HG ;
Allaire, PE ;
Bearnson, G ;
Khanwilkar, P .
ARTIFICIAL ORGANS, 2000, 24 (05) :377-385
[3]  
*ASTM INT, 1997, F184197 ASTM INT, P1326
[4]   THE TIME-DEPENDENT DEFORMATION OF A CAPSULE FREELY SUSPENDED IN A LINEAR SHEAR-FLOW [J].
BARTHESBIESEL, D ;
RALLISON, JM .
JOURNAL OF FLUID MECHANICS, 1981, 113 (DEC) :251-267
[5]   Biofluid simulations on Linux clusters [J].
Behr, M .
PARALLEL COMPUTATIONAL FLUID DYNAMICS: NEW FRONTIERS AND MULTI-DISCIPLINARY APPLICATIONS, PROCEEDINGS, 2003, :451-458
[6]  
Behr Marek, 2003, Computer Methods in Biomechanics and Biomedical Engineering, V6, P113, DOI 10.1080/1025584031000091650
[7]  
BLACKSHEAR PL, 1987, HDB BIOENGINEERING
[8]   3-DIMENSIONAL NUMERICAL PREDICTION OF STRESS LOADING OF BLOOD PARTICLES IN A CENTRIFUGAL PUMP [J].
BLUDSZUWEIT, C .
ARTIFICIAL ORGANS, 1995, 19 (07) :590-596
[9]   Computational fluid dynamics as a development tool for rotary blood pumps [J].
Burgreen, GW ;
Antaki, JF ;
Wu, ZJ ;
Holmes, AJ .
ARTIFICIAL ORGANS, 2001, 25 (05) :336-340
[10]  
CHAMPION J V, 1971, Biorheology, V8, P23