Direct determination of valproic acid in biological fluids by capillary electrophoresis with contactless conductivity detection

被引:35
作者
Belin, Gamze Kavran
Kraehenbuehl, Stephan
Hauser, Peter C.
机构
[1] Univ Geneva, Dept Chem, Lab Mass Spectrometry, CH-1211 Geneva 4, Switzerland
[2] Univ Basel Hosp, Div Clin Pharmacol & Toxicol, CH-4031 Basel, Switzerland
[3] Univ Basel Hosp, Res Dept, CH-4031 Basel, Switzerland
[4] Univ Basel, Dept Chem, CH-4003 Basel, Switzerland
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2007年 / 847卷 / 02期
关键词
valproic acid; contactless conductivity detection; capillary electrophoresis; biological fluids; caproic acid;
D O I
10.1016/j.jchromb.2006.10.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capacitively coupled contactless conductivity detection ((CD)-D-4) is a new technique providing high sensitivity in capillary electrophoresis (CE) especially for small ions that can otherwise only be determined with indirect methods. In this work, direct determination and validation of valproic acid (VPA) in biological fluids was achieved using CE with (CD)-D-4. VPA is of pharmacological interest because of its use in epilepsy and bipolar disorder. The running electrolyte solution used consisted of 10 mM[2-(N-morpholino)ethane sulfonic acid (MES)/DL-histidine (His) and 50 mu M hexadecyltrimethylammonium bromide (HTAB) at pH 6.0. Caproic acid (CA) was selected as internal standard (IS). Analyses of VPA in serum, plasma and urine samples were performed in less than 3 min. The interference of the sample matrix was reduced by deproteinization of the sample with acetonitrile (ACN). The effect of the solvent type and ratio on interference was investigated. The limits of detection (LOD) and quantitation (LOQ) of VIA in plasma samples were determined as 24 and 80 ng/ml, respectively. The method is linear between the 2 and 150 mu g/ml, covering well the therapeutic range of VPA (50-100 mu g/ml). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:205 / 209
页数:5
相关论文
共 57 条
[1]   RAPID CI-MS DETERMINATION OF VALPROIC ACID - ADAPTATION OF A GAS-CHROMATOGRAPHIC ASSAY [J].
BALKON, J .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1979, 3 (02) :78-79
[2]   SIMPLE AND RAPID GAS-CHROMATOGRAPHIC DETERMINATION OF VALPROIC ACID IN PLASMA [J].
BASARAN, N ;
HINCAL, F .
ANALYST, 1988, 113 (12) :1873-1874
[3]   Effect of cetyltrimethylammonium bromide on the migration of polyaromatic hydrocarbons in capillary electrokinetic chromatography [J].
Belin, G. Kavran ;
Erim, F. B. ;
Guelacar, F. O. .
TALANTA, 2006, 69 (03) :596-600
[4]   Capillary electrokinetic separation of polycyclic aromatic hydrocarbons using cetylpyridinium bromide [J].
Belin, GK ;
Erim, FB ;
Gülaçar, F .
POLYCYCLIC AROMATIC COMPOUNDS, 2004, 24 (4-5) :343-352
[5]   Anti-tumor mechanisms of valproate: A novel role for an old drug [J].
Blaheta, RA ;
Cinatl, J .
MEDICINAL RESEARCH REVIEWS, 2002, 22 (05) :492-511
[6]  
CHEN Z, 2001, ZHONGGUO YIYUAN YAOX, V21, P458
[7]  
Czarnecki W., 1999, ACTA POL PHARM, V56, P353
[8]  
da Silva JAF, 2002, J CHROMATOGR A, V942, P249
[9]  
da Silva JAF, 1998, ANAL CHEM, V70, P4339
[10]  
DEILLIANO BG, 1989, HRC-J HIGH RES CHROM, V12, P540