Amperometric flow injection analysis of organic thiols and proteins

被引:14
作者
Hidayat, A [1 ]
Hibbert, DB [1 ]
Alexander, PW [1 ]
机构
[1] UNIV TASMANIA,DEPT PHYS SCI,LAUNCESTON,TAS 7250,AUSTRALIA
关键词
thiols; flow injection analysis; cysteine;
D O I
10.1002/elan.1140080513
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The amperometric determination of thiols by injection into a mercury carrier stream is shown to be a sensitive method when using a tungsten wire as the working electrode in a three-electrode flow cell. Hg2+ gives sharp peaks when injected into phosphate buffer at pH 3.1 at an operating voltage of -0.24 V (against a Ag/AgCl reference electrode). Hg2+ was determined in the range 0.43 to 25.0 mu M with linear response. Injection of cysteine into the mercury carrier causes a decrease in the cathodic current, and sharp flow injection peaks are observed with a peak width of approximately 60s. Optimization of various parameters was performed, including buffer effects, mercury concentration, injection volume, and the effects of various cations and anions on the response were determined. Linear calibrations in the range 0.25 mu M to 100 mu M for cysteine and 1.3 to 1000 ng for the other thiols glutathione, thiourea, albumin, and DNA were found. The responses to cysteine and thiourea were most sensitive, and interference from silver and iodate was observed at concentrations in excess of the thiols. The method may be used as a rapid means of detecting thiols in various samples and as an HPLC detection method.
引用
收藏
页码:468 / 472
页数:5
相关论文
共 20 条
[1]   AUTOMATED CONTINUOUS-FLOW DETERMINATIONS OF SERUM-PROTEINS BY PULSE POLAROGRAPHY [J].
ALEXANDER, PW ;
SHAH, MH .
TALANTA, 1979, 26 (02) :97-102
[2]   POTENTIOMETRIC FLOW-INJECTION DETERMINATION OF COPPER-COMPLEXING ORGANIC-LIGANDS WITH A COPPER-WIRE INDICATING ELECTRODE [J].
ALEXANDER, PW ;
HADDAD, PR ;
TROJANOWICZ, M .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :151-163
[3]   TUNGSTEN SENSOR FOR AMPEROMETRIC DETECTION OF ORGANIC THIOLS AND PROTEINS [J].
ALEXANDER, PW ;
HIDAYAT, A ;
HIBBERT, DB .
ELECTROANALYSIS, 1995, 7 (03) :290-291
[4]   AMPEROMETRIC DETERMINATION OF METAL-IONS IN A FLOW-INJECTION SYSTEM WITH A COPPER-AMALGAM ELECTRODE [J].
ALEXANDER, PW ;
AKAPONGKUL, U .
ANALYTICA CHIMICA ACTA, 1983, 148 (APR) :103-109
[5]   DUAL ELECTRODE LIQUID-CHROMATOGRAPHY DETECTOR FOR THIOLS AND DISULFIDES [J].
ALLISON, LA ;
SHOUP, RE .
ANALYTICAL CHEMISTRY, 1983, 55 (01) :8-12
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF PENICILLAMINE IN WHOLE-BLOOD, PLASMA, AND URINE [J].
BERGSTROM, RF ;
KAY, DR ;
WAGNER, JG .
JOURNAL OF CHROMATOGRAPHY, 1981, 222 (03) :445-452
[7]  
COX A, 1990, CONT ELECTROANALYTIC, P267
[8]   FLOW-INJECTION AMPEROMETRIC DETERMINATION OF INSULIN BASED UPON ITS OXIDATION AT A MODIFIED ELECTRODE [J].
COX, JA ;
GRAY, TJ .
ANALYTICAL CHEMISTRY, 1989, 61 (21) :2462-2464
[9]   DETERMINATION OF SODIUM SALT OF 2-MERCAPTOPYRIDINE-N-OXIDE BY DIFFERENTIAL PULSE CATHODIC STRIPPING VOLTAMMETRY [J].
CSEJKA, DA ;
NAKOS, ST ;
DUBORD, EW .
ANALYTICAL CHEMISTRY, 1975, 47 (02) :322-324
[10]   ELECTROCHEMICAL FLOW-THROUGH DETECTOR FOR DETERMINATION OF CYSTINE AND RELATED COMPOUNDS [J].
EGGLI, R ;
ASPER, R .
ANALYTICA CHIMICA ACTA, 1978, 101 (02) :253-259