Determination of cadmium and lead in plastic material from waste electronic equipment using solid sampling graphite furnace atomic absorption spectrometry

被引:53
作者
Duarte, Alvaro T. [1 ,2 ]
Dessuy, Morgana B. [1 ,2 ]
Silva, Marcia M. [1 ,2 ]
Vale, Maria Goreti R. [1 ,2 ]
Welz, Bernhard [2 ,3 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, BR-91501970 Porto Alegre, RS, Brazil
[2] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq, INCT Energia & Ambiente, BR-40170115 Salvador, BA, Brazil
[3] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
关键词
WEEE; RoHS; Solid sampling graphite furnace atomic; absorption spectrometry; Cd; Pb; Polymers; HEAVY-METALS; LINE SOURCE; POLYMERS;
D O I
10.1016/j.microc.2010.02.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The European initiatives to minimize waste electric and electronic equipment (WEEE) and the restriction of hazardous substances (RoHS) had a major impact on the routine control of hazardous substances, including toxic trace metals, such as cadmium and lead, in all kinds of materials that are used in electric and electronic equipment. Instead of analyzing a whole computer, cell phone or television set, individual parts are normally investigated in order to simplify the analytical task. Plastic components are important constituents of electronic equipment, and a potential source of toxic trace metals that are added as catalysts, stabilizers or colorants. As high-tech plastic materials are designed to be resistant against chemical attack, they are usually difficult to bring into solution. A procedure is proposed in the present work that uses direct solid sampling graphite furnace atomic absorption spectrometry and calibration against aqueous standards. The method is sensitive, fast, and it does not require any sample preparation. The limits of detection of 0.1 mg kg(-1) for Cd and 0.6 mg kg(-1) for Pb are more than adequate for the purpose. Additional means are presented for reducing the sensitivity in order to cope with high analyte concentration. The method has been tested analyzing two certified reference materials, and good agreement with certified values has been obtained. (C) 2010 Elsevier BM. All rights reserved.
引用
收藏
页码:102 / 107
页数:6
相关论文
共 26 条
[1]  
[Anonymous], 2003, OFFICIAL J L, V37, P24, DOI DOI 10.1016/S1578-1550(11)70052-3
[2]  
[Anonymous], 2003, OFFICIAL J EUROPEAN, VL37, P19
[3]   Comparison of direct solid sampling and slurry sampling for the determination of cadmium in wheat flour by electrothermal atomic absorption spectrometry [J].
Araujo, Rennan G. O. ;
Oleszczuk, Nedio ;
Rampazzo, Roger T. ;
Costa, Pedro A. ;
Silva, Mdrcia M. ;
Vale, Maria Goreti R. ;
Welz, Bernhard ;
Ferreira, Sergio L. C. .
TALANTA, 2008, 77 (01) :400-406
[4]   An analysis of some environmental consequences of European electrical and electronic waste regulation [J].
Barba-Gutierrez, Y. ;
Adenso-Diaz, B. ;
Hopp, M. .
RESOURCES CONSERVATION AND RECYCLING, 2008, 52 (03) :481-495
[5]   RAPID-DETERMINATION OF LEAD BY ANALYSIS OF SOLID SAMPLES USING GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BELARRA, MA ;
LAVILLA, I ;
ANZANO, JM ;
CASTILLO, JR .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (07) :1075-1078
[6]   Determination of catalyst metal residues in polymers by X-ray fluorescence [J].
Bichinho, KM ;
Pires, GP ;
Stedile, FC ;
dos Santos, JHZ ;
Wolf, CR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (05) :599-604
[7]   Mechanical recycling of waste electric and electronic equipment: a review [J].
Cui, JR ;
Forssberg, E .
JOURNAL OF HAZARDOUS MATERIALS, 2003, 99 (03) :243-263
[8]  
Cusack P., 2006, PLASTICS ADDITIVES C, V8, P46, DOI DOI 10.1016/S1464-391X(06)70584-0
[9]   Comparison of direct sampling and emulsion analysis using a filter furnace for the determination of lead in crude oil by graphite furnace atomic absorption spectrometry [J].
Damin, Isabel C. F. ;
Dessuy, Morgana B. ;
Castilhos, Tamara S. ;
Silva, Marcia M. ;
Vale, Maria Goreti R. ;
Welz, Bernhard ;
Katskov, Dmitri A. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (06) :530-536
[10]   Novel strategies for rapid trace element analysis of polyamide by graphite furnace atomic absorption spectrometry and inductively coupled plasma mass spectrometry.: Dissolution in an organic solvent versus direct solid sampling approaches [J].
De Schrijver, Isabel ;
Aramendia, Maite ;
Resano, Martin ;
Dumoulin, Ann ;
Vanhaecke, Frank .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (04) :500-507