Rapid Ablation for Atrial Flutter. Background: The maximum voltage-guided (MVG) approach to ablation for atrial flutter targets high-amplitude signals along the cavotricuspid isthmus (CTI). It is based on the observation that the isthmus is often composed of bundles of conducting tissue and the hypothesis that these bundles manifest as high-amplitude electrograms, providing targets for selective ablation. We aim to identify patient and procedural factors that correlate with rapid isthmus ablation. Methods: All patients undergoing CTI ablation at our center from January 2005 to May 2006 were included. Patients were divided into outcome groups relative to the median value for total ablation time. The two groups were compared according to patient and procedural variables, using multivariate regression methods. Results: Seventy-six patients were assessed with mean age 60.2 +/- 10.6 years; 63 (82.9%) were male. Mean ablation time to bidirectional block across the CTI was 6.85 +/- 5.87 min (range 0.68-28.7); median 4.77 min. Seventy-six percent of patients required less than 5 min total ablation time until bidirectional block was achieved. Variables independently associated with a short ablation time were the presence of sinus rhythm at start of ablation (P = 0.0050, odds ratio (OR) 8.03), high mean temperature among all ablations (P = 0.019, OR 17.81), and low variability of mean power among all ablations (P = 0.0048, OR 19.26). Conclusions: Using the MVG approach to atrial flutter ablation, shorter total ablation times are observed among patients in sinus rhythm at the onset of ablation, with higher mean temperature among ablation lesions, and less variability of power between ablations.
引用
收藏
页码:612 / 616
页数:5
相关论文
共 17 条
[1]   Prospective randomized comparison of cooled radiofrequency versus standard radiofrequency energy for ablation of typical atrial flutter [J].
Atiga, WL ;
Worley, SJ ;
Hummel, J ;
Berger, RD ;
Gohn, DC ;
Mandalakas, NJ ;
Kalbfleisch, S ;
Halperin, H ;
Donahue, K ;
Tomaselli, G ;
Calkins, H ;
Daoud, E .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (08) :1172-1178
[2]   The inferior right atrial isthmus:: Further architectural insights for current and coming ablation technologies [J].
Cabrera, JA ;
Sánchez-Quintana, D ;
Farré, J ;
Rubio, JM ;
Ho, SY .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (04) :402-408
[3]   Angiographic anatomy of the inferior right atrial isthmus in patients with and without history of common atrial flutter [J].
Cabrera, JA ;
Sanchez-Quintana, D ;
Ho, SY ;
Medina, A ;
Wanguemert, F ;
Gross, E ;
Grillo, J ;
Hernandez, E ;
Anderson, RH .
CIRCULATION, 1999, 99 (23) :3017-3023
[4]   Effect of isthmus anatomy and ablation catheter on radiofrequency catheter ablation of the cavotricuspid isthmus [J].
Da Costa, A ;
Faure, E ;
Thévenin, J ;
Messier, M ;
Bernard, S ;
Abdel, K ;
Robin, C ;
Romeyer, C ;
Isaaz, K .
CIRCULATION, 2004, 110 (09) :1030-1035
[5]   Radiofrequency catheter ablation of type 1 atrial flutter using large-tip 8-or 10-mm electrode catheters and a high-output radiofrequency energy generator - Results of a multicenter safety and efficacy study [J].
Feld, G ;
Wharton, M ;
Plumb, V ;
Daoud, E ;
Friehling, T ;
Epstein, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (08) :1466-1472
[6]   Use of different catheter ablation technologies for treatment of typical atrial flutter: Acute results and long-term follow-up [J].
Marrouche, NF ;
Schweikert, R ;
Saliba, W ;
Pavia, SV ;
Martin, DO ;
Dresing, T ;
Cole, C ;
Balaban, K ;
Saad, E ;
Perez-Lugones, A ;
Bash, D ;
Tchou, P ;
Natale, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (03) :743-746
[7]   Prospective randomized comparison of antiarrhythmic therapy versus first-line radiofrequency ablation in patients with atrial flutter [J].
Natale, A ;
Newby, KH ;
Pisanó, E ;
Leonelli, F ;
Fanelli, R ;
Potenza, D ;
Beheiry, S ;
Tomassoni, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (07) :1898-1904
[8]   Atrial electrogram amplitude and efficacy of cavotricuspid isthmus ablation for atrial flutter [J].
Ozaydin, M ;
Tada, H ;
Chugh, A ;
Scharf, C ;
Lai, SWK ;
Pelosi, F ;
Knight, BP ;
Morady, F ;
Oral, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (09) :1859-1863
[9]   Radio frequency catheter ablation of atrial flutter - Further insights into the various types of isthmus block: Application to ablation during sinus rhythm [J].
Poty, H ;
Saoudi, N ;
Nair, M ;
Anselme, F ;
Letac, B .
CIRCULATION, 1996, 94 (12) :3204-3213
[10]   Cavotricuspid isthmus conduction is dependent on underlying anatomic bundle architecture: Observations using a maximum voltage-guided ablation technique [J].
Redfearn, Damian P. ;
Skanes, Allan C. ;
Gula, Lorne J. ;
Krahn, Andrew D. ;
Yee, Raymond ;
Klein, George J. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (08) :832-838